Brush (anti-static)
419.1
4
Circuit Board
441
1
Emitter Pin
439
2
Fan/Blower (Papst)
426
1
Filter Assembly
A425
1
Filter Retainer
448
1
Filters (10 pack)
A411
0
Filters (50 pack)
A411/5
0
Finger Guard
427
1
Instruction Manual
405
1
Ionizer
438
1
LED Lens (green)
450
1
Magnet
406
8
Nylatron Guide
451
4
On/Off Switch
418
1
Pull Tab
449
1
Retainer (lid screw)
436
1
Rubber Feet (4)
407
1
Screw (base)
431
4
Screw (brush)
420
8
Screw (fan)
428
8
Screw (lid)
435
1
Socket (6-pin DIN)
442
1
Transformer
402
1
Power Cord
1
North America, Japan
685.0
Continental Europe
685.1
Switzerland
685.2
United Kingdom
685.3
Australia
685.4
Italy
685.5
MAINTENANCE PROCEDURES
PARTS LIST
E
N
G
L
I
S
H
E
N
G
L
I
S
H
These steps are VERY important to the proper
performance of your machine. These procedures should
be performed every week.
At least four times a year remove the four (4) cleaning brushes. There are two (2)
screws which hold each brush in place. Wash in a gentle shampoo, rinse, comb wet
brush straight and let air dry. (DO NOT USE ELECTRIC HAIR DRYER, IT WILL
DAMAGE THE BRUSH.) When replacing the brushes, rotate brushes like the tires
on you car. You will notice the upper brushes have oversized mounting holes which
allow adjustment of the brush tension. Mount the lower brushes before installing
the upper brushes. The position of the upper brush should just “contact” the
lower brush.
Wipe off the emitter pins located under the
lid. To do this
TURN POWER OFF.
Loosen screw
on lid and lift lid, use a cotton swab or soft cloth
to remove any dust or dirt that has accumulated
on both pins. Care should be taken as these pins
are very sharp.
Remove the filter retainer in the rear of the
machine by pulling the special tab. Remove the
white foam H.E.P.A. filter. Replace or wash the
filter in water. Place the filter retainer in the bottom
and “snap” the top into place.
Vacuum or blow out brushes to remove
debris and dirt trapped or lodged in the brushes.
TURN POWER OFF.
Loosen screw on lid and lift.
Vacuum inside of machine carefully to remove any
loose materials.
1.
2.
3.
Your machine is covered by a two year warranty which covers all parts. Any part will be replaced at no
charge within the warranty period by furnishing the serial number and date of purchase.
THANK YOU FOR CHOOSING A STATICVAC FILM CLEANING MACHINE.
1-800-624-3204 or 1-941-951-2432
or FAX 1.941.955.5992
internet: http://www.kinetronics.com
e mail: [email protected]
Should you have any questions call our Service Department at:
SV-4400U