TROUBLE SHOOTING GUIDE

PROBLEM

POSSIBLE CAUSES

ACTION

1. No Output

120 VAC supply not con

-

nected

Connect power supply

Check AC distribution panel 

for proper operation

External Fuses Blown

Check for Reverse Polarity
Replace Fuses with same 

type and rating

Short Circuit

Trace Circuits for possible 
fault

Unit has shutdown due 

to overheating

Check air flow
Allow unit to cool

Unit has shutdown due 

to over voltage (Also see 

item 5 below)

Check input voltage

Converter will shut down if 
the input voltage exceeds 
13.2 Volts

Correct Input Voltage

2. External Fuses 

Blown

Reverse Battery Hook 

Up

Correct Hook up and replace 

Fuses with same type and 

rating

3. Converter cycles 
on & off

Compartment gets too 
hot

Check air flow to the con

-

verter

Improve Ventilation to the 
compartment

4. Low Output

Excessive Load for 
Converter

Reduce load requirements or 

Install Larger Converter

Input Voltage not be-

tween 105-130 VAC

Correct input supply voltage

Bad Battery Cell(s)

Replace Battery

5. Intermittent or no 

Output on Genera

-

tor, works on Shore 
Power

Unit has shutdown due 

to over voltage

Add another load to the 

generator, this may reduce 
the “spikes” to an acceptable 
level

Some generators exhibit 
excessive voltage spikes 

on the AC power output, 

this may cuase the over 
voltage protection to 
shut the unit down

Contact generator manufac-
turer for possible defect in the 
generator

Содержание KIPS12-45

Страница 1: ... OWNERS MANUAL Constantly monitors the battery voltage and automatically selects one of four operating modes NORMAL BOOST STORAGE DESULFATION Computer Controlled Charging System The Intelligent way to charge and maintain your vehicle s battery 45 AMP 60 AMP 80 AMP ...

Страница 2: ... have been shorted If this condition should occur the converter first limits the cur rent Should the condition continue to exist the converter then reduces the current output within thousandths of a second The Kinetik Intelligent Power Converter was designed to protect itself Once the short circuit has been corrected the converter will automatically return to normal operating conditions THERMAL PR...

Страница 3: ...built in This is a microprocessor controlled device which constantly monitors the battery and then automatically adjusts the converter output volt age based on its charge status There are four 4 operating Modes NORMAL BOOST STORAGE and DESULFATION EQUALIZE Each mode is automati cally selected by the microprocessor and ensures a fast yet safe recharge for your battery See the chart below for detail...

Страница 4: ...for a battery or other filtering NOTICE At normal input voltages the full load rated capacity is available At input voltages less than 105 VAC the converter may not supply full rated output capacity The full rated load is available for load battery charging or both When functioning as a regulated battery charger the Kinetik converters have a nominal voltage output of 13 6 VDC The system was design...

Страница 5: ...etik Intelligent Power Converters are not designed for zero clear ance compartments Unobstructed ventilation is required ATTENTION 1 USE A 5 32 HEX DRIVER TO TIGHTEN THE OUTPUT SCREWS DO NOT EXCEED 50 IN LB TORQUE 2 THE OUTPUT TERMINALS ARE RATED FOR 2 TO 14 GA COPPER OR ALUMINUM WIRE 3 THE KINETIK INTELLIGENT POWER CONVERTERS ARE NOT WEATHER TIGHT OR DESIGNED FOR WET LOCATION MOUNTING THEY MUST B...

Страница 6: ... Hook Up Correct Hook up and replace Fuses with same type and rating 3 Converter cycles on off Compartment gets too hot Check air flow to the con verter Improve Ventilation to the compartment 4 Low Output Excessive Load for Converter Reduce load requirements or Install Larger Converter Input Voltage not be tween 105 130 VAC Correct input supply voltage Bad Battery Cell s Replace Battery 5 Intermit...

Страница 7: ...0 Watts Output 13 6 VDC 60 Amps Dimensions 3 6H x 9 15L x 9W Weight 5 8lbs KINETIK KIPS12 80 Input 105 130 VAC 60 Hz 1300 Watts Output 13 6 VDC 80 Amps Dimensions 3 6H x 11 65L x 9W Weight 7 5lbs CAUTION RISK OF FIRE Chassis bonding wire must be a separate wire ran directly from the Grounding Lug provided on the side of the converter DO NOT connect Output Negative to chassis using the same wire ...

Страница 8: ...OFITS LOST SAVINGS LOSS OF USE OF ENJOYMENT OR F OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAMAGES FOR PERSONAL INJURY THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE PROOF OF PURCHASE A warranty claim m...

Отзывы: