Connecting to your computer

The Savant Elite USB foot switch may be connected to any USB port. For the first time, it is
best to connect it 

after 

your computer has booted up and is logged in (if you have a network)

so that you can see the “new device detected” message.

 

If you need to use a USB extension

cable, connect without it the first time to be sure the foot switch is working correctly, then
test it with the extension cable. When working correctly, the green LED should be on
continuously.

Drivers

The device has two separate electronic identities: one when it is in “play mode” and a
separate identity when it is in “program mode.” Play mode is supported by generic drivers
provided by the operating system and is normally installed automatically (see details below).

A special driver is required if you wish to customize or reprogram the device. You may
download the driver at http://www.kinesis.com/ tech_support/ downloads.htm. If you wish to
receive a CD-ROM, please contact Kinesis by telephone (800-454-6374) or by email
([email protected]) and provide the serial number of your device and your mailing address.
A fee will be charged for the CD-ROM option.

Important installation note: before trying to customize the foot switch, first install and test
the device in “play mode” as described below. Then if you wish to re-program the foot
switch, disconnect the device before installing the programming driver, and carefully follow
the instructions in the chapter C

USTOMIZING 

Y

OUR 

F

OOT 

S

WITCH

 for installing the

“programming driver.”

Installing “Play Mode”

It is strongly recommended that you use the foot switch at least briefly with its factory
programming before customizing it. The Savant Elite foot switch is shipped with its internal
programming switch in the “Play mode.” Do not move the switch to “programming mode” at
this time.

Play mode for Windows 2000/XP/Vista/Windows 7

When you first plug in the device, the red LED will illuminate. Windows 2000, Windows
XP, Windows Vista, and Windows 7 will install “Play Mode” drivers automatically, using
generic files available from the operating system. This process is usually complete within
less than a minute, and when completed, the red LED will go out and the green LED will
illuminate. This process will be repeated the first time you move the device to a different

11

Содержание Savant Elite FS10J

Страница 1: ...Savant Elite USB Programmable Foot Switch Family USER S MANUAL...

Страница 2: ......

Страница 3: ...ity These products are fully operational and programmable with Windows 2000 Windows XP Windows Vista Windows 7 The downloadable programming driver is preconfigured to use Windows XP compatibility mode...

Страница 4: ...for help Warning To assure continued FCC compliance the user must use only shielded interfacing cables when connecting to computer or peripheral Also any unauthorized changes or modifications to this...

Страница 5: ...e first 6 Repetitive strain safety warning 6 Features and compatibility 7 Installation 11 Custom programming your foot switch actions 13 Safety cleaning and maintenance 21 Troubleshooting and technica...

Страница 6: ...r and workstation setup Exercise good judgment in placing reasonable limits on your computer usage time every day Ensure that you take reasonable rest breaks from computer use during the course of the...

Страница 7: ...rted under most platforms supporting USB input devices a programming driver which is available for download from the Kinesis website is supported under Windows 2000 Windows XP Windows VISTA Once custo...

Страница 8: ...edal is held down but at a slower rate which is not affected by the keyboard repeat delay rate set in the control panel These features may be changed using special commands Slow output If normal progr...

Страница 9: ...is com or 800 454 6374 Model specific Features The various models of Savant Elite programmable devices have unique features which are described below Single pedal bundled with control module FS10J Thi...

Страница 10: ...edals The three pedal model provides the highest performance where small size is not critcal The outer two pedals may be adjusted approximately closer to the middle pedal using a small philips screwdr...

Страница 11: ...de the serial number of your device and your mailing address A fee will be charged for the CD ROM option Important installation note before trying to customize the foot switch first install and test t...

Страница 12: ...As long as the green LED is glowing continuously not flashing the device is in play mode and working properly For now don t worry about re programming your foot switch before you have confirmed that i...

Страница 13: ...tch Your regular keyboard is not required for the Savant Elite foot switch to operate once it has been programmed If your computer will boot with only a USB keyboard attached the Savant Elite should s...

Страница 14: ...lashing indicating that programming mode is active 4 You may now program one or more pedals see below or invert the device to return the slide switch back to play mode When in play mode the green LED...

Страница 15: ...d to provide special settings or mouse button actions Your computer will generate a brief trilling sound when the pedal is pressed to conclude successful programming of one of these actions Also the g...

Страница 16: ...ctional actions and is provided in all major operating systems The most common usage of Mousekeys is for the keypad 5 to perform a left mouse button action and a macro performing a double keypad 5 wil...

Страница 17: ...witch back to the right Advanced programming features A number of special features can be programmed However it is recommended to use these features only when you have become familiar with basic opera...

Страница 18: ...n is pressed and released Another application is to send one action when the pedal is pressed and a different action when the pedal is released For example in transcription software you might want to...

Страница 19: ...c 5 The foot switch can be programmed with 0 5 second delays When programming one 0 5 second delay is inserted for each Esc 5 sequence Setting Capslock remembered during playback Esc 8 turn off with E...

Страница 20: ...20...

Страница 21: ...ironment such as an operating room requiring water proof e g IPX8 devices Equivalent IPX8 rated products are available from Kinesis by special order To inquire email sales kinesis com or call 800 454...

Страница 22: ...22...

Страница 23: ...the key codes for example it may be rebooting Too many key codes were entered The maximum is approximately 750 per pedal There may be an intermittent cable connection Check all cables for proper conne...

Страница 24: ...prior to product repair For any repair whether or not it is covered by your warranty you must contact Kinesis to explain the problem provide certain information and get an RMA number to write on your...

Страница 25: ...ound carrier at no charge Repair parts and replacement Product may be either reconditioned or new Kinesis retains the right to charge a service fee or return shipping fee on Product sent for warranty...

Страница 26: ......

Страница 27: ......

Страница 28: ...KINESIS CORPORATION WWW KINESIS COM 800 454 6374 SALES KINESIS COM...

Отзывы: