Kinder Camber Скачать руководство пользователя страница 1

Camber

DECORATIVE PEBBLE FUEL EFFECT GAS FIRE

Installation and Maintenance Instructions
Hand these instructions to the user

Model No’s KRDP**MN are for use on Natural Gas (G20) at a supply

pressure of 20 mbar in G.B. / I.E.

** denotes fascia / colour variant

Содержание Camber

Страница 1: ...E FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s KRDP MN are for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E denote...

Страница 2: ...ection 2 Installation of Fire 2 1 Unpacking the fire 10 2 2 Installing the fire box 10 16 2 3 Gas tightness and burner pressure 17 Section 3 Assembling Fuel Bed and Commissioning 3 1 Assembling the ce...

Страница 3: ...r 520mm Height with camber trim no spacer 610mm Depth from mounting face to rear panel without spacer fitted 170mm Depth from mounting face to rear panel with spacer fitted 120mm Gas Connection 8mm Co...

Страница 4: ...onents Concrete Flue Blocks 8 I S 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appli ance when installed in G B When Inst...

Страница 5: ...150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue only ser...

Страница 6: ...ied out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 375 and 440 mm wide and between 550 and 570mm high...

Страница 7: ...ble for use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick providing the minimum depth of the fireplace exceeds 260mm If the depth is less than 260mm t...

Страница 8: ...ance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installed as to ensure proper operation with any type of gas fire In some instances of this flue...

Страница 9: ...h the fire is operated The following are impor tant warnings relating to this spillage monitoring system 1 The spillage monitoring system must not be adjusted by the installer 2 The spillage monitorin...

Страница 10: ...on book 1off Camber Ashpan 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch diameter l...

Страница 11: ...age and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps prese...

Страница 12: ...the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 5a 5b below for suggested concealed pipe layouts Fig 5a Fi...

Страница 13: ...which in turn will damage the burner and control systems of the product Fig 6 below shows a correctly sealed installation Fig 6 PLEASE NOTE 13 BFM EUROPE LTD WILL NOT BE LIABLE FOR GUARANTEE CLAIMS T...

Страница 14: ...pacer The foam seal supplied must be fitted around the perimeter of the spacer in a goalpost arrangement to ensure a seal is achieved to the fireplace To fit using the preferred cable method proceed a...

Страница 15: ...ing nut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 8 below Fig 8 j Evenly tighte...

Страница 16: ...e caused to the gas control valve on the fire The other firebox fixing method is as follows In installations where the cable method is not suitable e g loose masonary in rear of fire opening the fireb...

Страница 17: ...nt screw Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector SECTION 3 ASSEMBLING FUEL BED AND COMMISSIONING 3 1 ASSEMB...

Страница 18: ...correctly located onto the lip on the burner front ceramic support See fig 11 below Fig 11 c Pick pebbles A to E and arrange along the the front rail ensuring that they are evenly spaced Use the rece...

Страница 19: ...t pebbles K L M and arrange along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 14 below Fig 14 f Select the two small pebbles J N and position to...

Страница 20: ...lation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance When replacing these articles...

Страница 21: ...t but the pilot will remain lit g Slightly depress the control knob and turn to the off position the pilot will now be extinguished WARNING If the fire goes out for any reason or is turned off and it...

Страница 22: ...running on maximum and all interconnecting doors open f After ensuring that the fire is safe to use it should be left on high position to fully warm up During this time a slight odour may be noticed t...

Страница 23: ...safe location Remove the loose pebbles from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the burner heat shield and r...

Страница 24: ...e Oxy Pilot Assembly Note Because this appliance is fitted with an atmosphere sensing Oxy Pilot it is not possible to replace the thermocouple separately because the thermocouple position is factory s...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...Pebble Set B 106490 Camber Black Fuel bed Complete Ceramic Set B 106420 Camber Black Fuel bed Fuel bed Matrix B 106430 Camber Black Fuel bed Front Rail B 106440 Camber Black Fuel bed Pebble Set B 106...

Отзывы: