kincrome KP87005 Скачать руководство пользователя страница 5

5

TEMPERATURE & SAFETY PROTECTION: 

INTERNAL OVERHEAT PROTECTION: The charger has a built-in overheat and an
overload electronic circuit. This protects the charger from being damaged if overheated
or overloaded and will automatically decrease the charging current. Once the units in-
ternal temperature decreases to a safe level, the charger will resume normal charging.

SAFETY TIMER PROTECTION: The charger has safety timers for every stage. If the
battery Voltage doesn’t reach a certain Voltage within a certain time, the unit will stop
charging as it’s highly likely that you’re attempting to charge a severely discharged or
heavily sulphated battery. If any of the stages time out, the charger will immediately
stop charging in order to protect the battery. This will be indicated  with the fault LED
flashing slowly.

REVERSE POLARITY: The charger has reverse polarity protection. If the charger output
leads are connected reverse polarity, the fault LED will come ON and the charger will be
disabled. Simply unplug  the charger from AC power and then connect the output leads
to the correct polarity.

•  SHORT CIRCUIT PROTECTION: The charger will automatically turn OFF if the output 

leads are short circuited and the fault LED will come ON. This prevents the charger from
being damaged if the positive and negative crocodile clips or the optional ring terminals 
accidently touch each other while the charger is turned ON.

ECO MODE: This Kincrome Battery Charger has a built in ultra low power consumption
circuit. If AC power is connected and the battery is disconnected, after 10 seconds the
charger will automatically go into an ECO mode. During this mode the power drawn
is less than 0.36W which totals 0.01kWh per day power consumption. If AC power is
connected and the battery is connected, once the battery is fully charged and during the
long term maintenance stage, the total power consumption is around 0.03kWh per day.

Both the selected Charge rate and Battery type LED’s will flash GREEN to indicate ECO

mode.

BATTERY TYPES & CAPACITY:

Suits 12V conventional lead acid batteries (VRLA) AGM, Calcium, Gel & Wet. 
The Ah (Ampere Hours) capacities shown below are to be used as a general guide only.
Some batteries may be able to handle a higher charge current. Refer to the battery 
manufacturers specifications and recommendations for your charging requirements. 

Charge Rate:

1A

8A

12A

Charging

3 - 20Ah 24 - 160Ah 36 - 240Ah

Maintaining

< 100Ah

< 240Ah

<360Ah

SMART 9-STAGE BATTERY CHARGER 

& REJUVENATOR 

12V 12 AMP

ELECTRICAL PARTS & ACCESSORIES: 

AC Power Cord:

1.8m with SAA 3 Pin AU Plug

DC Output Lead:

1.2m with quick connect plug

Charging Leads: 

Quick connect 60cm Crocodile Clip Harness

KP87005 manual_OC1206U_OC1212U_Troy.indd   4

29/03/2018   3:57 PM

Quick connect 60cm Ring Terminal Harness

Содержание KP87005

Страница 1: ...NATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECOND...

Страница 2: ...nator Please take the time to carefully read and understand this manual before using this product Table of Contents Know Your Product 2 IMPORTANT Safety Advice and Warnings 3 Main Features 3 Temperatu...

Страница 3: ...attery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery terminals with any t...

Страница 4: ...fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance...

Страница 5: ...e positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Kincrome Battery Charger has a built in ultra low power...

Страница 6: ...N FAST FLASH REJUVENATION SLOW FLASH SOFT START CHARGING ON BULK CHARGING FAULT LED RED ON SHORT CIRCUIT REVERSE POLARITY OR REJUVENATION FAILED IF BULK LED ALSO FLASHING SLOW RED FLASHING OVER TEMPER...

Страница 7: ...g terminal lead to the vehicle s chassis Fig 2 WARNING DO NOT connect the BLACK lead to the carburettor or fuel lines If Positively Earthed FIRST Connect the BLACK Crocodile clip or optional ring term...

Страница 8: ...sn t reach 11V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing Bulk Charging BLUE Bulk LED ON Charge Voltage dep...

Страница 9: ...d 24 7 to ensure your battery is well maintained and kept 100 fully charged Float mode will maintain the battery at a constant 13 6V Long Term Maintenance Full GREEN LED ON During long term maintenanc...

Страница 10: ...10 CHARGING CURVE Natio Natio 3 Lak Scor ABN 4 SMART 9 STAGE BATTERY CHARGER REJUVENATOR 12V 12 AMP KP87005 manual_OC1206U_OC1212U_Troy indd 9 29 03 2018 3 58 PM...

Страница 11: ...com au 11 Warranty given by Kincrome Australia Pty Ltd of 3 Lakeview Drive Caribbean Park Scoresby Victoria Tel 1300 657 528 The applicable warranty period 24 months commences on the date that the pro...

Отзывы: