kincrome KP87003 Скачать руководство пользователя страница 8

8

4. The Charging Process

•  Qualification - Battery Condition Check

 

When the charger is first switched ON it checks the battery condition to determine  
whether the battery needs reconditioning. During this qualification process it checks 
the internal impedance and initial Voltage of the battery and it will determine how much 
charge current, if any that the battery will accept. 

• 

Enhanced Battery Rejuvenation - BLUE Bulk LED Flashing Fast

 

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a high 
Voltage equalising and peak pulse reconditioning charge is used to repair the sulphated 
battery. This unique patented feature will break down and dissolve the lead-sulphate 
crystal build up on the battery plates which will extend the life of your battery. It can also 
balance out high concentrations of acid. The equalisation Voltage will be 16V DC  
maximum. If the battery Voltage doesn’t reach 9V DC within 24 hours, the Rejuvenation 
process will time out.

• 

Soft Start Charging - BLUE Bulk LED Flashing Slow

 

Gently charges the battery using a reduced charge output until the battery Voltages 
reaches 11V. If the battery Voltage doesn’t reach 11V within 6 hours, the safety timer 
protection will stop the unit from charging and the RED Fault LED and BLUE Bulk LED 
will start flashing.

• 

Bulk Charging - BLUE Bulk LED ON

 (Charge Voltage depends on battery type selection)

 

Uses the maximum selected charge output until the battery Voltage reaches 
14.1/14.4/14.7V DC. If the battery Voltage doesn’t reach this within 24 hours, the safety 
timer protection will stop the unit from charging and the RED Fault LED will start  
flashing and the BLUE Bulk LED will be ON.

• 

Absorption Charging - GREEN Absorption LED ON

 

Uses a constant Voltage while reducing the charging output current to ensure the  
battery receives a full charge without overcharging the battery. 

3. Connect the battery charger to Mains Power (240AC)

•  The charger will automatically start when AC Pin Plug is connected and switched ON. 

•  IMPORTANT

: Please make sure the correct Battery Type and your desired Charge Rate 

is selected to suit your battery by pressing the Select Buttons within the first 5 minutes 
of charging. For Example do not charge a Gel Battery on the Calcium Battery Type  
setting as this may damage your battery and / or reduce your battery life. 

Note:

 If the Fault Indicator LED illuminates RED, please check your connections as it’s 

likely that the Positive (RED (+)) and Negative (BLACK (-)) Leads are reversed.

SMART 9 STAGE BATTERY CHARGER 

& REJUVENATOR  12V 6 AMP

KP87003 manual_OC1206U_OC1212U_Troy.indd   6

29/03/2018   3:24 PM

Содержание KP87003

Страница 1: ...LY PATENTED BATTERY REJUVENATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED B...

Страница 2: ...ories 5 Temperature Safety Protection 5 Battery Types Capacity 5 Understanding your Product 6 Operation Charging Instructions 7 9 Charging Curve 10 Troubleshooting 11 Warranty 12 SPECIFICATION Know Yo...

Страница 3: ...acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery terminals with any type of metal tool or piece of jewellery as th...

Страница 4: ...he battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance with a special...

Страница 5: ...e positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Kincrome Battery Charger has a built in ultra low power...

Страница 6: ...SH ON FAST FLASH REJUVENATION SLOW FLASH SOFT START CHARGING ON BULK CHARGING FAULT LED RED ON SHORT CIRCUIT REVERSE POLARITY OR REJUVENATION FAILED IF BULK LED ALSO FLASHING SLOW RED FLASHING OVER TE...

Страница 7: ...ed Most Common FIRST Connect the RED Crocodile clip or optional ring terminal lead to the battery terminal and then connect the BLACK Crocodile clip or optional ring terminal lead to the vehicle s cha...

Страница 8: ...t reach 11V within 6 hours the safety timer protection will stop the unit from charging and the RED Fault LED and BLUE Bulk LED will start flashing Bulk Charging BLUE Bulk LED ON Charge Voltage depend...

Страница 9: ...ed 24 7 to ensure your battery is well maintained and kept 100 fully charged Float mode will maintain the battery at a constant 13 6V Long Term Maintenance Full GREEN LED ON During long term maintenan...

Страница 10: ...10 CHARGING CURVE SMART 9 STAGE BATTERY CHARGER REJUVENATOR 12V 6 AMP KP87003 manual_OC1206U_OC1212U_Troy indd 8 29 03 2018 3 24 PM...

Страница 11: ...lacement Move battery charger to a cooler environment The full float light won t come ON Fault RED LED is Flashing OR Full GREEN LED is Flashing Battery Ah capacity too large for the battery charger a...

Страница 12: ...r replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure For further details please visit www kincrome com au or call us Due to minor changes in desi...