background image

10

DIGITAL AUTO RANGING MULTIMETER

10) Care, Maintenance & Storage

Auto Power Off

If you dont operate the Kincrome K8315 Multimeter for about 15 minutes, it will turn OFF automatically. To turn it on again, just roate 
the range switch or press a button.

Note:

 If you press the “

” button to turn on the meter, the automatic power-off function will be disabled.

Battery Replacement

If the sign “

” appears on the display, it indicates that the batteries should be replaced.  Remove the screws and open the back 

case, replace the exhausted battery with new batteries (NEDA 1604, 6F22 or equivalent).

Fuse Replacement

Fuse rarely needs replacement and is often caused as a result of operators error. To replace the fuses, remove the testing leads (10) 
from the power source, open the battery cover and replace the damaged one with a new fuse of the specified rating. Reinstall the 
battery cover and lock the cover.

11) Spare Parts

Part No

Description

Quantity

K8315-1

Storage Bag

1

K8315-2

Test Leads (10)

1

K8315-3

Multi Function Adaptor (11)

1

K8315-4

Fuse

1

* Please Note:

 Kincrome reserve the right to change spare parts at any time without notice. 

11) Warranty

Warranty given by Kincrome Australia Pty Ltd of 3 Lakeview Drive, Caribbean Park, Scoresby, Victoria (Tel 1300 657 528). 
The applicable warranty period (12 months) commences on the date that the product is purchased. If this product has materials or 
workmanship defects (other than defects caused by abnormal or non warranted use) you can, at your cost, send the product to place 
of purchase, an authorised Kincrome service agent or one of Kincromes addresses for repair or replacement. Your rights under this 
warranty are in addition to any other rights you have under the Australian Consumer Law or other applicable laws. Our goods come 
with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major 
failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 
replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. For further details please visit 
www.kincrome.com.au or call us. Due to minor changes in design or manufacture, the product you purchase may sometimes differ 
from the one shown on the packaging..
IMPORTANT! If the tool fails to operate correctly,  call customer service on 1800 657 528 for advice on the best resolution for your 
situation. If a resolution cannot be achieved over the phone please take the tool and all related accessories to an authorised service 
centre or place of purchase showing proof of purchase for assistance.

Содержание K8315

Страница 1: ...AUTO RANGING DIGITAL MULTIMETER K8315 ED1 May 17 LARGE DIGITAL DISPLAY 12 MONTH WARRANTY AC DC VOLTAGE CURRENT MEASUREMENT CAT II SAFETY RATING CAT III TEST LEAD SAFETY RATING...

Страница 2: ...ct or 9 DATA H Button Hold 10 Test Leads CAT III 11 Multi Function Capacitance Transistor Adaptor Model No K8315 Analog Display 42 segments updates 12 5 times sec Digital Display 3999 Counts updates 2...

Страница 3: ...before using the Meter e Verify the Meter s operation by measuring a known voltage before and after using it Do not use the Meter if it operates abnormally Protection may be impaired If in doubt have...

Страница 4: ...tion Wear approved safety eye protection 3 Service a Tool service must be performed only by qualified repair personnel b When servicing a tool use only identical replacement parts Use only authorized...

Страница 5: ...nd Low Battery Fuse Diode Continuity Test Conforms to European Union Directive Double Insulated 6 Multimeters Function Table Model DCV ACV DCA ACA hFE CAP Hz K8315 8 Multimeter Product Specifications...

Страница 6: ...ge hFE Test Current Test Voltage PNP NPN 0 1000 lb 2 A Vce 1V DC Current Range Resolution Accuracy 400 A 0 1 A 0 8 of rdg 5dgts 4000 A 1 A 40mA 10 A 400mA 100 A 4A 1mA 1 5 of rdg 3dgts 10A 10mA Cautio...

Страница 7: ...u must wait 15 minutes before reusing the multimeter Overload Protection mA jack F0 5A 600V Fuse 10A jack F10A 600V Fuse Max Input Current mA jack 400mA 10A jack 10A Voltage Drop 400 A 40mA and 4A ran...

Страница 8: ...nt do not attempt to take any voltage measurements which may exceed 600V DC or 600V AC rms Do not apply more than 600V DC or 600V AC rms between the common terminals and the earth ground 1 Connect the...

Страница 9: ...high voltage capacitors before measuring resistance 1 Connect the BLACK test lead 10 to the COM jack 6 and RED lead 10 to the V jack 7 Note The polarity of the RED test lead 10 is positive 1 Set the...

Страница 10: ...he COM Jack 6 and the mA jack 5 Ensure the writing on the Multi Function Capacitance Transistor 11 is correctly orientated Identify whether the transistor is NPN or PNP type and locate Emitter base an...

Страница 11: ...Tel 1300 657 528 The applicable warranty period 12 months commences on the date that the product is purchased If this product has materials or workmanship defects other than defects caused by abnorma...

Страница 12: ...11 DIGITAL AUTO RANGING MULTIMETER Notes...

Страница 13: ...www kincrome com au...

Отзывы: