2 PIECE VEHICLE POSITIONING JACKS
Trouble Shooting
Symptom
Cause
Remedy
Pump unit will not work
1. Release valve (4) is open.
2. Dirt on valve seals.
3. Worn seals.
1. Close the release valve (4).
2. Replace the oil.
3. Call Kincrome Customer Service.
Pump unit will not produce
pressure
1. The reservoir could be overfilled or low
on hydraulic fluid.
2. Air trapped in the system.
3. Leaking seals.
1. Check the fluid level. Do not
overfill.
2. Open the release valve (4).
Pump the handle a couple of full
strokes. Close the release valve (4).
3. Contact Kincrome customer Service
Pump unit will retract
completely
1. Air trapped in the system.
2. The reservoir could be overfilled or low
on hydraulic fluid.
1. Open the release valve (4) .
Pump the pump peddle (2) a couple of
full strokes. Close the release.
2. Check the fluid level is correct. Do not
overfill.
Ram will not fully extend
Low on hydraulic fluid.
1. Check that oil level is correct.
2. Check oil with ram fully retracted.
3. Add hydraulic fluid.
Fluid leaking from release
valve
Worn O-ring.
1. Contact Kincrome customer Service
Fluid leaking around
hydraulic ram piston
Worn seal or piston.
Please contact Kincrome customer
service.