Warning:

 

if the generator has to be connected to 

commercial power grid,

 

make sure that the chief 

power switch must be shut off.

 

Otherwise the 

sudden recovery of commercial power supply 
may cause damage to generator or appliance

and even a fire accident.

18

5. When connect the generator to home power       

    circuit.

 

Be sure that a skilled electrician does  

    the job.

 

Improper connecting between the 

    generator and appliance may cause damage of
    the generator or appliance

and even a fire

This charging function cannot replace charging 
with a special battery charger! This device does 
not have a charging current regulator or an automatic 
shutdown when the battery is fully charged!
Be sure to inform yourself about the design of 
your automotive battery, as well as its proper 
charging and maintenance! Contact a qualified 
specialist! Strictly adhere to the safety rules and 
instructions of the battery manufacturer!
Measure the voltage regularly while recharging 
the automotive battery! When the voltage of the 
battery reaches 12.5 V, the battery is then fully 
charged!

Содержание K10101

Страница 1: ...Generator...

Страница 2: ...the start up power required by an appliance when first being started simultaneously 1 Determine which appliances are to be run at a given time by the generator Add up the Rated Watts of each appliance...

Страница 3: ...Petrol...

Страница 4: ...the dust or fumes Keep bystanders children and visitors away while operating a generator Provide barriers or shields as needed 1 2 Electrical Safety Grounded tools must be plugged into an outlet prope...

Страница 5: ...ny way Double insulation eliminates the need for the three wire grounded cord and grounded power supply system Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerator...

Страница 6: ...ance with all relevant local state and federal electrical codes and standards and other regulations where applicable The generator must be earth grounded for fixed installations in accordance with all...

Страница 7: ...red by the generator disconnect the equipment from its power input Keep all electrical equipment clean and dry Replace any wiring where the insulation is cracked cut abraded or otherwise degraded Repl...

Страница 8: ...loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make s...

Страница 9: ...your application The correct usage will make your generator do the job better and safer at the rate for which it is designed for Do not use the generator if the power switch can not be turned to ON or...

Страница 10: ...ged generator Tag damaged generators Do not use until repaired Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the generator s operation If...

Страница 11: ...ormed by unqualified personnel could result in a risk of injury When servicing a generator use only identical replacement parts Follow all appropriate instructions in this manual Use of unauthorized p...

Страница 12: ...he earth ground connection should be completed by a licensed electrician Any separate fuel storage or generator supply facility must be built or installed in full compliance with all relevant local st...

Страница 13: ...RODUCTION 1 fuel tank 2 muffler 3 Earth terminal 4 A C plug socket 5 carburetor throttle valve 6 starter handle 7 fuel cork 8 air cleaner 9 pipe support 10 spark plug 11 fuel tank cap 12 AC breaker 13...

Страница 14: ...ng generator on a level ground 1 Turn out the oil filter cap and clean the dipstick with a clean cloth 2 Insert the dipstick back into the filter hole without turning 3 In the case that the oil level...

Страница 15: ...13 3 2 Fuel level 1 Open the fuel tank cap 2 Check the fuel oil level and refill if necessary 3 Refill up to the shoulder of the fuel filter 4 Reinstall the fuel tank cap...

Страница 16: ...lip and dismantle the air cleaner housing or unscrew the nuts and air cleaner cover 2 Unscrew the nut and washer and dismantle the filter element for several times 3 Dismantle the filter element 5 Sla...

Страница 17: ...Part 4 STARTING OF GENERATOR 15 cork...

Страница 18: ...wattage for start up Do not exceed the current limit specified for any one socket 3 Be sure that all appliances are in good working condition before connecting them to the generator If an appliance is...

Страница 19: ...is not suitable to be used for charging 12 V automotive batteries The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded when ther...

Страница 20: ...damage of the generator or appliance and even a fire This charging function cannot replace charging with a special battery charger This device does not have a charging current regulator or an automat...

Страница 21: ...PING OF GENERATOR 1 Switch off the AC breaker 2 Turn the generator switch to off position 3 Set the fuel cork to off position Note To stop the generator in emergency turn the generator switch to off p...

Страница 22: ...re performing any maintenance If the engine must be ran make sure the area is well ventilated The exhaust contains poisonous carbon monoxide gas After engine has been used clean it immediately with a...

Страница 23: ...empty the machine oil in the crankshaft 21 Oil filter Spark plug Valve clearance Check adjust Cylinder cover wash clean Fuel tank wash Wash if necessary replace every 3 years clean clean Item Daily ch...

Страница 24: ...ine oil up to the upper level 5 Reinstall the dipstick Machine oil 4 stroke petrol engine oil SE SF from API Service Classification or SAE 10W 30 equivalent to SG class Low air temperature below 10 C...

Страница 25: ...C SE SF from API Service Classification or SAE10W 30 equivalent to SG class Air cleaner refer to page 8 Air cleaner Spark plug 1 Dismantle the spark plug high pressure cap 2 Dismantle the spark plug...

Страница 26: ...install the spark plug and high pressure cap 6 3 Fuel filter maintenance 1 Set the fuel cork to off position and dismantle the fuel filter cup 2 Clean the fuel filter cup thoroughly 3 Mount a new rubb...

Страница 27: ...Screw off the fuel drain plug and empty the fuel inside the carburetor 2 Turn off the oil filter plug and oil drain plug and empty the machine oil inside the crankcase 3 Reinstall the oil drain plug 4...

Страница 28: ...rload the Generator 3 Contact Authorized Service Facility 4 Contact Authorized Service Facility Engine will not start or starts and runs rough 1 Dirty air filter 2 Out of petrol 3 Stale petrol 4 Spark...

Страница 29: ...Facility Engine lacks power 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced 1 See Don t Overload the Generator 2 Replace air filter 3 Contact Authorized Service Facility Engine hu...

Страница 30: ......

Страница 31: ...ur rights under this warranty are in addition to any other rights you have under the Australian Consumer Law or other applicable laws Our goods come with guarantees that cannot be excluded under the A...

Отзывы: