background image

All Pictures shown are for illustration purpose only. Actual product may vary due to product enhancement. 

www.kimray.com

ROTARY TO LINEAR ADAPTER

QUICK START GUIDE

CAUTION

When ordered, the valve configuration and construction materials 

were selected to meet specific pressure, temperature, pressure drop 

and fluid conditions.  Since some body/trim material combinations are 

limited in their pressure drop and temperature ranges, do not subject 

the high pressure valve to any other conditions without first contacting 

the Kimray Inc. sales office or a sales / applications representative.

CAUTION

Prior to installing, the instructions provided herein should be completely 

reviewed and understood before operating or repairing this equipment.

 

All CAUTION and WARNING notes must be strictly observed to 

prevent personal injury or equipment damage.

Description

The R2L Adapter enables the Kimray High Pressure Control Valve 

(HPCV) to be controlled by quarter-turn electric actuators. This solution 

is a durable, simple, and effective way to maintain control within an 

automated production site.

The Kimray R2L Adapter translates rotary motion into linear motion. As 

an extra feature, this product is designed with a series of springs with 

a live loaded stem in order to compensate for seat wear. The Kimray 

R2L Adapter allows any ISO-5211 rotary actuator to be coupled with an 

industry standard Kimray High Pressure Control Valve.

Installation

If the R2L Adapter has been shipped separately for installation 

on a Kimray Valve Body, or if the R2L Adapter was removed for 

maintenance, mount the R2L Adapter by following the instructions 

presented in this section. Inspect the surface of the Mounting Yoke and 

clean the mating valve surface to remove scale, chips, and debris.

The Kimray R2L is used with Kimray High Pressure Control Valves 

such as through or angle body valves. In the R2L Actuator, the spiral 

rotation of the Rotary Shaft by means of a rotary Actuator is translated 

into linear motion, opening, and closing the valve. The stroke length 

is achieved with a 90° rotation of the shaft, clockwise to close. As the 

Plug contacts the seat, a series of Springs become loaded to ensure 

valve closure in the event of seat creep or wear.

1.  Mount the Actuator onto the Valve using supplied bolts and tighten.

NOTE: 

Tighten the bolts in a crisscross pattern to avoid any miss alignment. 

DO NOT OVER TIGHTEN. For 1in. and 2in. tighten bolts from 25-30 

ft/lbs torque.

2.  Install Travel Indicator Assembly on Stem and tighten the bolts in 

the Coupling Block with a socket.

NOTE: 

For the quarter turn Actuator, follow manufacturer recommendation 

for the installation and operation notes.

3.  Install the valve with the arrow on the body pointing in the direction 

of flow. The arrow signifies that the device will operate properly in the 

direction of flow indicated and will not necessarily prevent flow in the 

opposite direction.

4.  Install the valve using good piping practices. For flanged bodies 

use a suitable gasket between the body and the pipeline flanges. 

For threaded (NPT) bodies, use TFE tape or pipe thread sealant on 

external pipe threads. Use good practices.

NOTE: 

Use good electrical wiring practices and consult with an electrician. 

Figure 2

Figure 1