BioMax2 / KBio2-Online
Installation and Programming Manual
Page
55 of 91
9.6.6. ApplyCFG
Function: It restarts the machine for the new configuration values to be applied.
If bit 3 of
CFG_ECHO
), the
BioMax2 / KBio2-Online
electronics may “return the response” to the
instruction. In reality, this will be
the first event after electronics start-up and, therefore, it will only be received if the
CFG_EventCH
parameter is correctly configured and, in the event of communications
via UDP, if a remote port other than
0000
is defined.
In general, if this event is enabled, it will be seen when the electronics is started even in
the event of a restart due to an exception. In the latter case, information for the Kimaldi
Electronic Technical Service will be obtained.
Instruction
OP
0x09
NA
0x0000
ARG
None
Response
None (a soft-reset of the entire machine occurs)
Event
OP
0x09
NA
0x0000 or 0x0014
ARG
If 0 arguments, normal start-up.
If 20 arguments, automatic restart after an exception:
Bytes 1..20: information for Kimaldi Electronics.