EL220
Accent Lights
Installation Instructions
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical
Code. Portable spear or surface mounts using a cord and plug must be plugged into a receptacle
protected by a Ground Fault Circuit Interrupter (GFCI) in accordance with the National Electrical Code.
Failure to take these steps may result in serious personal injury.
CAUTION: Lighted lamp is HOT! Do not touch hot lens, guard or enclosure. Fixtures are approved for
above grade installation only.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, lenses must be kept clean
and free of dirt, dust, leaves, trash and mineral deposits from water. For optimum performance a regularly
scheduled maintenance program should be followed. KEEP THIS SHEET FOR FUTURE REFERENCE.
Revised 7/
16
/10 ECN 100715008 Status 13 Part No. 95440
Your KIM fixture(s) is supplied with
K
” NPSM male mounting threads and locknut.
Tools Required
:
Thread Sealant
Flat Blade Screwdriver
Phillips Screwdriver
Adjustable Wrench
B
"
Allen Wrench
Installation Instructions:
Make certain the electrical supply is
OFF
before starting installation instructions.
1. Coat threads with sealant to keep
moisture from entering J-Box.
2. Tighten coupling onto mounting
device. (Consult KIM Landscape
Catalog for mounting device
options.)
4. Loosen screw, adjust fixture angle,
and tighten screw.
EL210
3. Install fixture onto coupling. Attach
fixture leads observing polarity,
i.e.; green-to-ground, white-to-
common, and black-to-voltage.
5. Loosen setscrew, adjust fixture
rotation, and tighten setscrew.
!
6. Push lamp gasket onto lamp.
Caution: Do not press gasket
too far onto lamp or seal with
socket will be lost. (See gasket
illustration on page 2.)
Lamp Gasket
!