![Kilsen KAL734C Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/kilsen/kal734c/kal734c_installation-sheet_1967157002.webp)
2 / 16
P/N 10-5151-501-104-01 • ISS 28NOV14
The module uses four addresses: The configured address plus
the next three numbers (for example,. 201, 202 and 203 if the
configured address is 200).
Status LED
The status LED is lit constantly during alarm.
Maintenance and testing
Basic maintenance consists of a yearly inspection. Do not
modify internal wiring or circuitry.
To test the module:
1. Configure the module as an output to be activated by a
detector or manual call point.
2. Activate a detector or manual call point associated with
the module.
3. If the status LED and control panel fail to indicate the test
all connections should be checked and the module
address verified.
Specifications
Operating voltage
22 to 38 VDC
Loop current consumption:
at 24 VDC (standby)
at 35 VDC (standby)
Alarm
110 µA
135 µA
<10 mA
Current consumption:
24 VDC aux. supply
(standby)*
24 VDC aux. supply (alarm)*
100 µA
<10 mA
Relay contact rating
30 VDC / 0.5 A or 50 VAC / 0.5 A
Operating temperature
Storage temperature
−10 to +50ºC
−10 to +70ºC
Relative humidity
10 to 95% (noncondensing)
Weight
835 g
Dimensions
223 × 173 × 80 mm
* Excluding loop devices
Regulatory information
This section includes both regulatory information and a
summary on the declared performance according to the
Construction Products Regulation 305/2011. For detailed
information refer to the product Declaration of Performance.
Certification
Certification body
0370
Declaration of
Performance number
360-4109-0899
Year of first CE marking
08
Product identification
KAL734C
Intended use
See DoP point 3
Essential characteristics See DoP point 9
Manufacturer
UTC CCS Manufacturing Polska Sp.
Z o.o. Ul. Kolejowa 24. 39-100 Ropczyce,
Poland
Authorized EU manufacturing
representative: UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
2012/19/EU (WEEE directive): Products
marked with this symbol cannot be
disposed of as unsorted municipal waste in
the European Union. For proper recycling,
return this product to your local supplier
upon the purchase of equivalent new
equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
Contact information
For contact information, see www. utcfssecurityproducts.eu.
ES: Instrucciónes de instalación
Descripción
El módulo KAL734C proporciona cuatro salidas de relé libre de
potencial al bucle del sistema de incendios. Cada relé permite
la instalación de contactos comunes (C), normalmente abiertos
(NA) y normalmente cerrados (NC).
El módulo puede utilizarse con cualquier dispositivo y la opción
de contacto utilizada establecerá el evento deseado.
Instalación
Precaución:
Consulte el estándar EN54:14 y las normativas
locales para obtener información acerca de las directrices de
planificación, diseño, instalación, funcionamiento, utilización y
mantenimiento del sistema.
Instalación del módulo
Desconecte la fuente de alimentación del sistema de incendios
e instale el módulo en la carcasa protectora proporcionada.
Conecte el hilo apantallado del cable de bucle al tornillo de
tierra.
Una fuente de alimentación auxiliar debe proporcionar
alimentación de 24 V al módulo.
Conexión
Los conectores del módulo, el microinterruptor y el indicador
LED de estado se muestran en la Figura 1:
1. Tornillo de tierra
2. LED de estado
3. Conectores de bucle
4. Conexiones de alimentación auxiliares
5. Microinterruptor
6. Relay output connectors 1 to 4 (C, NC, NO)
Direccionamiento
Cada módulo necesita una dirección numérica entre 128 y 252
para su identificación. Ésta se puede configurar con los
Содержание KAL734C
Страница 13: ...P N 10 5151 501 104 01 ISS 28NOV14 13 16 ...
Страница 14: ...14 16 P N 10 5151 501 104 01 ISS 28NOV14 ...
Страница 15: ...P N 10 5151 501 104 01 ISS 28NOV14 15 16 ...
Страница 16: ...16 16 P N 10 5151 501 104 01 ISS 28NOV14 ...