Sirius SD Logger
–
User Manual
This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.
Kilowatt Labs, Inc. |
12
8.
CS
–
Calibration State Flags (0000000 -> 00111111)
bit 0
–
Current Calibration (Zero not Calibrated and 1 for Calibrated)
bit 1
–
No Load Current Calibration
bit 2
–
Temperature Calibration
bit 3
–
Capacity Configuration
bit 4
–
Serial Number Configuration
bit 5
–
QC Passed Flag
bit 6
–
Reserved
bit 7
–
Reserved
9.
SOC
–
State of Charge (integer value)
10.
RR
–
Battery Terminal State (Zero means SSR is OFF and 1 means SSR is ON)
11.
BL
–
Balancing State
1
–
Balancing is OFF (Default)
2
–
Balancing is ON
12.
RTC
–
Status of real time clock of the Sirius Module.
0
–
RTC is not set or RTC is not working
1
–
RTC is running with proper time
5
–
RTC needs to configure
13.
SD
–
State of SD Card (inside the Module).
1
–
Working
2
–
Error
3
–
Standby: Standby means SD Card or RTC has problem and SD card brought to idle to avoid
dangerous errors.
14.
CHBL
–
Balancing while charging flag. This is not applicable when connecting the modules in series.
0
–
Disabled (Default)
1
–
Enabled