Sirius Capacitor Module
–
User Manual
Model Number -7100-48-B-2C-TM-SD-A-G
This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.
Kilowatt Labs, Inc. |
33
Q. How to update the Firmware.
A. New Firmware is uploaded to
https://www.amberandwaseem.com/
.Always check the website for an
update.
Q. The Module doesn’t seem to show correct State of Charge (SOC).
A. The Module is using the previous data to correct the state of charge in the long run. Charge the Module to
maximum Voltage and then discharge it to cut-off Voltage and repeat the process several times to correct the
SOC. Note that open voltage is not directly related to SOC.
Q. Can the Sirius Module be installed standing vertically with the connection facing up without potentially
stressing the cells inside the Module?
A. Yes, but NOT in a movable\vibrating position.
Q. What is the difference between the ‘’balancing “and “auto balancing” in “set Config” tab in Sirius
VIEW?
A. Balancing: Balancing can be activated from any voltage level when the Module is in standby mode (Zero
current). When all the cells get balance, the balancing will stop. The time required to balance all cells depends
on cells condition.
Auto balancing:
Auto balancing is activated automatically during charging when the cells get unbalanced.
Note that it is activated only when the Module Voltage reaches ~52 V.
Q. Can balancing and auto balancing options be activated at a same time?
A. Yes.
Q. When to use Sirius Config?
A. The Module is received with full settings and the most updated firmware, however, if you want to calibrate
parameters (current, voltage, date and time, alarm, temperature) you can use Sirius Config for calibrating. For
more information contact your Reseller.
12.
Revision:
Steps to operate Module in Series is been added on page 25.