![Kilowatt Labs 3550-48-B-1.7C-M-SD-A-G Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/kilowatt-labs/3550-48-b-1-7c-m-sd-a-g/3550-48-b-1-7c-m-sd-a-g_user-manual_1967118030.webp)
Sirius Capacitor Module
–
User Manual
Model Number - 3550-48-B-1.7C-M-SD-A-G
This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.
Kilowatt Labs, Inc. |
30
•
Different current within the maximum limit specified by the test equipment manufacturer can be
applied to the test.
•
We took test currents in the range of 20-70A with current steps of 10.
Test Process:
Step 1: Rest (open circuit):
•
Record test time, test current, and voltage at the start of the test (t1, I1, V1).
Step 2: Charge Cycle:
•
Charge voltage to its maximum voltage.
•
Record test time, test current, voltage and total charge energy at the end of charge cycle (t2, I2,
V2, E1).
Step 3: Discharge Cycle:
•
Discharge Module to its minimum voltage.
•
Record test time, test current, voltage and total discharge energy at the end of discharge cycle (t3,
I3, V3, E2).
Step 4: Round Trip Efficiency Calculation:
Round trip efficiency = [
total discharge energy (E2)
total charge energy (E1)
] × 100
13.2 Performance Data:
Total Voltage During Charge Cycle:
Ambient temperature During Charge Cycle: