4

apparent  damage  resulting  from  an  accident,  neglect  or  abuse  or  improper
handling;  damage  caused  by  high  humidity,  liquid  or  foreign  substance
infiltration;  damage  due  to  use  in  temperatures  outside  the  “Operating
temperature” range; use near a source of Electro-magnetic or RF interference.
In Canada, Charder Medical Scales are repaired by Kilotech Inc. at Kilotech’s
facility in Montreal QC.  The shipper is responsible to properly pack and return
the scale to Kilotech and is responsible for any damage caused to the device
because of improper packaging.
An RMA Return Merchandise Authorization Number must be obtained prior to
shipping.    Customer  must  adhere  to  shipping  instructions  on  the  RMA.    The
RMA  can be obtained by calling 1-800-694-4445.
If the customer is not a Kilotech dealer, any payment will need to be secured
by Kilotech on a credit card prior to the scale being returned to the customer.

DISPOSING OF THE SCALE

This  product  is  not  to  be  treated  as  regular  household  waste,  but  should  be
handed in to an electrical/electronic equipment-recycling center.

Содержание MS-4201 Baby

Страница 1: ...MS 4202L Adult MS 4201 Baby USER MANUAL...

Страница 2: ...4445 TABLE OF CONTENTS PREFACE 2 GENERAL INFORMATION 2 SAFETY INSTRUCTION 2 ENVIROMENTAL 3 CLEANING 3 MAINTENANCE 3 WEIGHING OPERATION 3 WARRANTY LIABILITY 3 DISPOSING OF THE SCALE 4 SPECIFICATIONS 5...

Страница 3: ...and maintenance of the device The end user must take every precaution to insure the safety of this device and the people using the device Neither Kilotech Inc nor the manufacturer shall be liable for...

Страница 4: ...regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur contact your local dealer WEIGHING OPERATION Before reading detailed instructions on h...

Страница 5: ...k and return the scale to Kilotech and is responsible for any damage caused to the device because of improper packaging An RMA Return Merchandise Authorization Number must be obtained prior to shippin...

Страница 6: ...lb 200kg x 50g 440lb x 0 1lb Tray Yes No Units of Measure kg lb Function keys ON ZERO OFF HOLD BMI TARE Stabilisation Time 1 2 seconds Operating Temp 0 C 40 C at 80 RH Power supply Six AA size alkalin...

Страница 7: ...6 SETTINGS Auto Off Time Adjustment Auto Off time feature affects how long will shut off automatically without any operation Press TARE key for 3 seconds to enter setting mode Press...

Страница 8: ...1 Press ZERO for 3 seconds to enter setting mode 2 Press TARE when A_OFF displayed 3 Press HOLD to select target time 60 120 240 300s OFF 4 Confirm your selection by pressing TARE again 5 Press HOLD...

Страница 9: ...be 50 cm 1 Press this key once to enter HOLD mode to lock weight value when weighing 2 Proceed with weighting Scale will beep when it has a stable reading and the hold indicator 7 is active 3 Press H...

Страница 10: ...y protective paper or napkin placed in the bowl can be deducted by pressing TARE key and obtaining zero Baby can then be weighed 4 Zero symbol 5 ON ZERO OFF MS 4201 MS 4202 MS 4202L only 6 Level indic...

Страница 11: ...10 INSTRUCTION FOR REPLACING BATTERY REMOVE THE BATTERY COVER ON BOTTOM SIDE OF SCALE PLEASE BE CAREFUL OF CORRECT BATTERY DIRECTIONS WHILE INSTALLATION...

Страница 12: ...11 INSTALL 6 1 5V AA BATTERIES YOU CAN ALSO USE THE ADAPTOR TO SUPPLY THE POWER...

Страница 13: ...f the trouble still exists please call your local service partner The loading is under limit when power on please reduce the loading If the trouble still exists please call your local service partner...

Страница 14: ...13 IN 0991 7008D...