Saturday
Now is PM 05:40
Corresponding Cursor
(1/8 duty flash)
Meter Clock Program Time set
Auto Copy Function:
It is possible to copy your programmed ON/OFF periods from Monday to the other days of the week. This can save programming time
if you wish the Graphic Timer to run the same ON/OFF programs every day. After you copy programming from
Mon
to the other days
of the week, you can still modify each day individually. This can save programming time if you wish the Graphic Timer to run the same
or similar ON/OFF programs most days. Adjust the other days accordingly following instructions for the
Program
mode after you follow
the below instructions to copy your programs.
1. While in
Program
mode, First reset all programming by holding the
Reset
key for 3 seconds. All segments in the outer LCD display
with switch off and the clock display will reset to
Mon
12:00 AM. Wait about 4 seconds for the single segment at 12:00 AM to begin
flashing.
2. Begin setting your program for Monday following instructions for the
Program
Mode. When you have completed your
Mon
programs, Press the
Day
button. All programs from
Mon
will be copied to the other six days of the week.
3. If desired, you can modify each day’s programming individually by following the instructions for
Program
mode.
Meter mode: (Function key
Meter
Volt key, Amp key or Watt key can show Voltage, Current, and Wattage).
1. Press
Function
key until
Meter
mode is selected. The current mode is indicated by a marker on the LCD above the mode name.
The main display will show the currently measured AC line voltage (in Volts).
2. Press the
Amp
key, main display will show the currently measured load current (in Amps).
3. Press the
Watt
key main display will show the currently measured appliance power consumption (in Watts).
4. Press the
Volt
key, main display will show the currently measured AC line voltage (in Volts).
5. If you press the
Reset
key, the cumulative appliance power consumption (in Kilowatt Hour-KWH) and Elapsed Time (in Days :
Hours : Minutes) will flash. If you then hold the
Reset
key for over one second, the unit will clear the cumulative KWH measurement
and will reset the elapsed time counter to zero. Be sure you have taken note of KWH measurements (if desired) before you reset as
they cannot be retrieved once reset.
KWH display (Meter mode):
1. The unit displays the total cumulative appliance power consumption in Kilowatt Hours (KWH). This is the unit your utility uses to
charge you for electricity. The unit will display KWH from 0.01 KWH to 9999 KWH. The decimal point will shift to accommodate a full
reading as the KWH measurement accumulates (as the connected appliance consumes power over time).
2. If you press the
Reset
key, the cumulative appliance power consumption (in Kilowatt Hour-KWH) and Elapsed Time (in Days :
Hours : Minutes) will flash. If you then hold the
Reset
key for over one second, the unit will clear the cumulative KWH measurement
and will reset the elapsed time counter to zero. Be sure you have taken note of KWH measurements (if desired) before you reset as
they cannot be retrieved once reset.
Elapsed Time display (Meter mode):
1. The unit displays the total cumulative elapsed time the appliance has been connected (since last reset) in Days: Hours: Minutes.
Time will be displayed from 000:00:00 to 999:23:59.
2. If you press the
Reset
key, the cumulative appliance power consumption (in Kilowatt Hour-KWH) and Elapsed Time (in Days :
Hours : Minutes) will flash. If you then hold the
Reset
key for over one second, the unit will clear the cumulative KWH measurement
and will reset the elapsed time counter to zero. Be sure you have taken note of KWH measurements (if desired) before you reset as