Kilews SKP-BC32HL-100N Скачать руководство пользователя страница 12

                                                                                       

                                                                                 

 

                                                                                                                                                                                           

 

11 

 
 
 

 

Push three seconds to enter the selection SL====SC====At====RC====SP====Ht====Lt====LL 

<Confirm> 

Function Name 

Set up 

Time and 

Value 

Description 

Buzz Time/ Light 

Manufactur

er Set-Up 

Value 

SL 

01~05 

Screw List 

--- 

---

 

SC 

01~99 

Counting number    / count-down only 

--- 

05 

At 

0.1~9.9 

Automatic zero time / Signal output time 

--- 

1.0 

RC 

0.1~9.9 

Slow start time 

--- 

--- 

SP 

L0~L9 

Speed of start

30

-100

  with rated L0~L9 

--- 

L0 

Ht 

0.0~9.9 

Ht time Stop time ( Show wrong as screwdriver 
can’t sop at set time after starting, can be used to 
test stripped screws   

Five buzz and LED red 
flash 

2.0 

Lt 

0.00~9.90 

Lt time will show wrong as screwdriver stops before Lt 
after starting, can test screw is not properly fastened at its 
position. .     

Two buzz and LED red 
flash 

0.00 

L

L

 

0.01~9.90 

Reconfirm time after fastening. 

--- 

0.00 

Backward to 

Count-Up ) 

1 COUNT 

When screwdriver is backward, the number will be 
back one 

--- 

--- 

Ln 

--- 

Automatic learning. 

LED keeps flash of light 

--- 

Buzzer 

 

Er 

Wrong 
Set-Up 

--- 

Wrong Set-Up, such as Lt

Ht 

Continue to ring and LED 

red flash. Press 

select/confirm show Er

 

--- 

 
PROCESS TO SET UP SYSTEM: 

1

 Please connect the cord, turn on the power switch until LED shows number. 

 
2

 Please press SELECT key over three seconds till buzzer making    sound, the panel will show              ,                                                       

to push UP/DOWN to decrease or increase the number, it can set up five units of number. 

 
3

 To press SELECT key, buzzer will sound, the panel will show                ,                    to push UP/DOWN to     

decrease or increase number, the    maximum    can set up 99.     
SC: To set up counting number. 

 
4

 To press SELECT, the screen will show                ,                  push UP/DOWN to increase or decrease       

number, the maximum can set up 9.9.   

At: Automatic set up CLEAR time. 

 
5

 To press SELECT, the screen will show                ,                    push UP/DOWN to increase or decrease   

number, the maximum can set up 9.9.   

Rc: To set up slow-start time. 

 
6

 To press SELECT, the screen will show                ,                ,      push UP/DOWN to increase or decrease   

number between L0~L9, the maximum can set up L9. 

SP

To set up speed of slow start. 

             
7

 To press SELECT, the screen will show                ,                    push UP/DOWN to increase or decrease   

number, the maximum can set up 9.9.   

Ht:

  Stop time. 

 
8

 To press SELECT, the screen will show              ,                push POWER key              , adjust decimals,     

UP/DOWN to increase or    decrease number, the maximum can set up 9.90. 
Lt: Set up Detect Start Time.”02.”means 0.02. 
 
 
 

  System setting 

Содержание SKP-BC32HL-100N

Страница 1: ...OPERATION AND MAINTENANCE MANUAL SKP BC32HL 100N In AC 100 240V Out DC 24V 32V KILEWS INDUSTRIAL CO LTD http www kilews com Y2F077 1 004...

Страница 2: ...n this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the...

Страница 3: ...itable for outdoor use Use of cord suitable for outdoor use reduces the risk of electric shock 3 Personal Safety a Stay alert watch what you are doing and use common sense when operating a power tool...

Страница 4: ...tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits ect in accordance with these instructions and in the manner intended fo...

Страница 5: ...the protection program to force Electric Screwdriver stop 8 Please do not disassemble Electric Screwdriver casually and try to repair it by self 9 When Controller is not in use please turn the main p...

Страница 6: ...F External Connection Input Confirm key Reset Key AffirmativeAffirmativeswitch recovery switch External Connection Output OK NG OK ALL Electric Screwdriver Speed Control HI LO Slow Start Size mm 200 1...

Страница 7: ...Selection Confirm Key 4 BC 6Pin Connector 15 Buzzer hole 5 WORK Light 16 Power point 6 OK Light 17 POWER SWITCH 7 N G Light 18 I O Inserting Hole Instruction 8 24V Light 19 Functional Dip Switch Inst...

Страница 8: ...t user set up number and unit during the process U1 No 1 setting number U2 No 2 setting number U3 No 3 setting number U4 No 4 setting number U5 No 5 setting number DOWN In system menu pressing the key...

Страница 9: ...0mA CN4 OK ALL Output Output one signal after finishing the setting value of screw number count Auto start If operator needs to input voltage please do not exceed DC 12V 10mA CN5 COM CN6 GATE Input co...

Страница 10: ...OR for confirming the new fastener that has reached the working table Therefore two confirming signals allow SKP BC32HL 100N to start the Electric Screwdriver running Select OFF means only need one SE...

Страница 11: ...use the Slow Start setting Rc SW6 Arrangement form The memory can save five units number user can push switch ON the system will automatically arrange five units easy for user to make arrangement at w...

Страница 12: ...PROCESS TO SET UP SYSTEM 1 Please connect the cord turn on the power switch until LED shows number 2 Please press SELECT key over three seconds till buzzer making sound the panel will show to push UP...

Страница 13: ...er if Ht and Lt is closer it will request more precise If the user press the push button of the screwdriver after Ht and Lt setting it is N G Ht Lt mainly set up the period of time If stop is within t...

Страница 14: ...use Electric Screwdriver Controller it should be grounded to avoid operator getting electrical shock This controller is equipped with 3 leading wires and 3 pins of grounding plug to fit for grounding...

Страница 15: ...e center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your ne...

Страница 16: ...15 1 2 3 4 5 6 7 1 SKD BC 2 KILEWS SKD BC KILEWS KILEWS 3 4 5 LED DC 1 2 3 4 5 KILEWS 6 7 8 9 OFF 10 SKP Lo 32V 4...

Страница 17: ...FF 1 Sensor 0 1 9 9 seconds 35 85 L0 L9 Rated speed 0 01 9 90 seconds 0 1 9 9 seconds On Off FF EF with LED and buzzer ON OFF OK NG OK ALL HI LO mm 200 130 100 Kg SKD BC512LF SKD BC512PF SKD BC519L SK...

Страница 18: ...17 NO NO 1 LED 12 2 HI LO 13 3 14 4 BC6PIN 15 5 16 6 OK 17 7 N G 18 8 24V 19 I O 9 32V 20 10 11 16 17 18 19 2 3 4 5 8 11 9 10 6 7 13 12 1 14 20 15...

Страница 19: ...18 POWER 8 7 LED WORK CLEAR SELECT 7 SL SC At RC SP Ht Lt LL CONFIRM DIP SW3 ON CONFIRM UP UP U1 1 U4 4 U2 2 U5 5 U3 3 DOWN UP U1 1 U4 4 U2 2 U5 5 U3 3 UP DOWN S RESET LC Un HL...

Страница 20: ...12V 10mA CN3 NG DC 12V 10mA CN4 OK ALL DC 12V 10mA At CN5 COM CN6 GATE OFF ON COM CN5 CN7 CLR CLEAR COM CN5 CN8 9 OK CN8 9 60V 400mA CN10 11 NG CN10 11 60V 400mA CN12 13 OK ALL CN12 13 60V 400mA CN14...

Страница 21: ...ELECT CONFIRM OFF SW4 ON SENSOR SKP BC32HL 100 SENSOR SENSOR SKP BC32HL 100 OFF SENSOR CONFIRM SENSOR SW2 ON SW3 OFF SW4 OFF Output SENSOR SW2 ON SW3 OFF SW4 ON SENSOR Er CONFIRM Er Output CONFIRM SW3...

Страница 22: ...ON CONFIRM SW2 ON SW3 ON SW4 OFF Output CONFIRM SENSOR CONFIRM SW2 ON SW3 ON SW4 ON Output CONFIRM CLEAR CONFIRM SENSOR CONFIRM SW5 OK N G Ht Lt ON SL SC At Rc SP SW6 5 ON 5 SW7 ON OFF 3 3 U4 SC 00 SW...

Страница 23: ...ECT UP DOWN 9 9 At 5 SELECT UP DOWN 9 9 Rc 6 SELECT UP DOWN L9 SP 7 SELECT UP DOWN 9 9 Ht 8 SELECT POWER UP DOWN 9 90 Lt 02 0 02 SL 01 05 SC 01 99 05 At 0 1 9 9 AUTO T 1 0 RC 0 1 9 9 SP L0 L9 35 85 L0...

Страница 24: ...R UP DOWN 9 90 LL 02 0 02 10 SELECT Ht Lt Ht Lt LL Start Lt 0 02 Ht 2 0 LL 1 0 OK N G N G OK Lt Ht N G Lt Lt Ht Ht Lt N G Ht Lt OK Lt Ht N G Ht Lt Lt 0 00 SELECT STOP STAR T OK N G Lt 0 5 s Ht 2 0 s L...

Страница 25: ...24 1 SW5 ON SW5 ON 2 ON LED CHECK 3 LED 0 0 LED DIP SW5 OFF Lt Ht 4 DIP SW5 OFF SELECT 7 SL SELECT SC SELECT At SELECT Rc SELECT SP SELECT Ht SELECT Lt SELECT LL SELECT CHECK ESD ON OFF...

Страница 26: ...O DES BY CHKD BY APPD BY TITLE CUSTOMER DWG NAME DWG NO MATERIAL DATE DATE DATE UNIT SHRINK SCALE SHT NO OF SHTS 2 3 4 5 16 20 21 6 12 15 17 11 7 8 10 9 18 22 25 25 26 23 19 24 26 25 30 31 28 29 30 33...

Страница 27: ...8 CONNECT 3P 1 6 EG50111 hypothesis PCB 1 28 X10068 BOLT 1 7 P11402 11 Hi Lo Switch ASS Y Hi Lo 1 29 X10067 WASHER 1 8 P11404 2 Key Switch ASS Y 1 30 CH20302 WASHER M4 6 9 P11404 1 Key 1 31 CH20401 BO...

Отзывы: