background image

2-6 

TOS

6200/6210

2

.5

Connecting the 

A

P

ower Cord

The p

o

we

r

 c

or

t

h

at

 is p

ro

vided v

ar

ies dependin

g

 

o

t

he des

t

in

at

i

o

n f

or

 

t

he p

ro

d

u

c

t

at

 

t

he f

a

c

tor

y

-

shipmen

t.

T

he 

AC

 power cord for 100 V system shown in Fig. 2-3 has a rated voltage

of 125 V

AC

I

f this 

AC

 power cord is used at the line voltage of a 200 V sys-

tem, replace the 

AC

 power cord with that satisfying that line voltage.

A

n appropriate 

AC

 power cord must be selected by qualified personnel. 

I

f

it is difficult to obtain the 

AC

 power cord, consult your Kikusui distributor/

agent.

The 

A

C p

o

we

r

 c

or

d inc

or

p

orat

es 

a

 disc

o

nnec

t

in

g

 device c

a

p

a

ble 

o

f is

o

l

at

in

g

 

t

he

p

ro

d

u

c

t

 f

ro

t

he 

A

C p

o

we

r

 line sh

ou

ld s

u

ch bec

o

me necess

ar

y

.

 C

o

nnec

t

 i

t

 

to

 

a

n

e

a

sily 

a

ccessible elec

tr

ic

a

out

le

t.

D

o

 n

ot

 

u

se 

t

he 

A

C p

o

we

r

 c

or

d p

ro

vided wi

t

t

he p

ro

d

u

c

t

 

a

a

 

A

C p

o

we

r

 c

or

d f

or

ot

he

r

 ins

tru

men

t

s

.

Fig. 2-3

AC

 power cord

P

rocedure

1.

C

heck that the power supply falls within the input line voltage range

indicated on the tester.

2.

C

heck that the P

O

W

ER

 switch of the tester is set to 

O

FF.

3.

C

onnect the 

AC

 power cord to the 

AC

 L

INE

 connector on the rear panel

of the tester.

Use 

t

he p

ro

vided p

o

we

r

 c

o

de 

or

 p

o

we

r

 c

o

de 

t

h

at

 is selec

t

ed by q

ua

lified pe

r-

s

o

nnel

.

4.

C

onnect the other end of the 

AC

 power cord to an electrical outlet.

F

or

 de

ta

ils 

o

t

he 

r

e

ar

 p

a

nel

,

 see 

3.2,

 “Re

ar

 

Pa

nel

.

W

ARNIN

G

NOTE

[85-AA-0003]
PLUG:NEMA5-15

Po

we

r

 c

or

d f

or

 

100

 V sys

t

em

R

at

ed v

o

l

tag

e: 

125

 V

A

C

R

at

ed c

urr

en

t

10

 

A

[85-10-0840]
PLUG:CEE7/7

[85-10-0790]
PLUG:GB1002

Po

we

r

 c

or

d f

or

 

200

 V sys

t

em

R

at

ed v

o

l

tag

e: 

250

 V

A

C

R

at

ed c

urr

en

t

10

 

A

Содержание tos6200

Страница 1: ...Part No Z1 003 302 IB008755 Aug 2011 OPERATION MANUAL EARTH CONTINUITY TESTER TOS6200 TOS6210...

Страница 2: ...e disposed of separately from general household waste This includes the power cords and other accessories bundled with the products When disposing of a product subject to these regulations please foll...

Страница 3: ...ltage is output here DANGER Indicates an imminently hazardous situation which if ignored will result in death or serious injury Indicates a potentially hazardous situation which if ignored could resul...

Страница 4: ...ose who have electrical knowl edge Purposes of use Do not use the product for purposes other than those described in the operation manual This product is not designed or manufactured for household use...

Страница 5: ...of the power cord Be sure to unplug the power cord before checking If any abnormality or failure is detected in the products stop using it immediately Unplug the power cord or disconnect the power co...

Страница 6: ...lied Test Lead TL11 TOS TL12 TOS 2 8 2 7 2 Optional Test Probe LP01 TOS LP02 TOS 2 10 2 7 3 Other Leads 2 11 2 7 4 Measurements Using Four Terminals 2 12 2 7 5 Measurements Using Two Terminals 2 12 2...

Страница 7: ...t to Output OVER HEAT 4 31 4 10 2 Overheating Protection OVER HEAT 4 32 4 10 3 Overload Protection OVER LOAD 4 32 4 10 4 Output Voltage Limitation VOLT LIMIT 4 33 4 10 5 Change in ENABLE Signal SIGNAL...

Страница 8: ...cing the Cooling Fan and Backup Battery 7 4 7 5 Calibration 7 4 7 6 In Case of Problems 7 5 Chapter 8 Specifications ___________________________________ 8 1 8 1 Basic Performance 8 2 8 2 Interface and...

Страница 9: ...TOS6200 6210 1 1 Chapter 1 General Gives an overview of the tester and describes its features and various options 1 1...

Страница 10: ...lease have ready the tester ROM version number and serial number indicated on the rear panel of your tester Fig 1 1 Opening screen for firmware version 1 01 Example of TOS6200 1 2 Introduction and Fea...

Страница 11: ...tion lines that require reduced cycle times 4 Compact and lightweight A new high ef ciency power supply achieving a power conversion ef ciency of 65 and large output TOS6200 150 VA TOS6210 220 VA make...

Страница 12: ...itions under the name of the destination of the DUT When test conditions need to be modi ed due to changes in the destination of the product or revised safety standards you can recall a set of test co...

Страница 13: ...S a test starts only when both switches are pressed simultaneously Functions OPERATE switch Test switches are enabled only when this switch is set to the ON position When it is set to the OFF position...

Страница 14: ...ster starting test stopping test operations Connect it to the OUTPUT and REMOTE terminals on the tester s front panel Maximum rating LP01 TOS 30 A LP02 TOS 60 A Cable length 2 m Accessory LOW Test Lea...

Страница 15: ...TOS6200 6210 2 1 Chapter 2 Installation and Preparation for Use Describes the steps from unpacking to installation to preparation required before switching on POWER 2 2...

Страница 16: ...ing those cables see 5 2 SIGNAL I O Connector and Chapter 6 GPIB and RS 232C Packing materials may be used for later transport of the product so it is recom mended that they be retained The power cord...

Страница 17: ...ge 90 R H or less no dew condensation is allowed Condensation may occur even within the operating humidity range In that case do not start using the product until condensation dries up completely Do n...

Страница 18: ...CD screen or improve the operability of the keys Pull the provided feet forward onto the oor until you hear them click Fig 2 2 How to use the feet Do not use the rubber strips on the sides as feet Use...

Страница 19: ...rear panel Using the tester outside the permitted range will result in erratic function or failure Operate the product with the supply voltage within the voltage range required TOS6200 The symbol ind...

Страница 20: ...ome necessary Connect it to an easily accessible electrical outlet Do not use the AC power cord provided with the product as a AC power cord for other instruments Fig 2 3 AC power cord Procedure 1 Che...

Страница 21: ...no grounding is provided a malfunction may result from external noise and or the product may generate a large amount of noise There are two ways to ground the tester as given below Connect the AC pow...

Страница 22: ...o the OUTPUT terminals The nominal sectional area of this wire is inadequate for such currents and burning may result This product carries a large current and consequently generates a strong magnetic...

Страница 23: ...n the banana plug side to the HIGH side of the SAMPLING terminals Check that the connections are secure Improper terminal connections can result in inaccurate measurements and burns or injury resultin...

Страница 24: ...mproper terminal connections can result in inaccurate measurements and burns or injury resulting from heat generated by contact resistance at the terminals 1 Turn off the POWER switch of the Tester 2...

Страница 25: ...p termi nals appropriate for the sectional area of the current output line Select wires on the basis of the following criteria Resistance values with respect to the nominal sectional areas of wires ar...

Страница 26: ...rehand For more information see 4 2 6 Offset Canceling Function OUTPUT LOW HIGH LOW HIGH SAMPLING r1 r3 r5 r6 r7 r8 r4 r2 R2 R3 R4 DUT Device Under Test r1 to r8 Contact resistance R1 to R4 Resistance...

Страница 27: ...of the test probe or lead during the test or immediately after test since they are at high temperature Testing from the protective conductor terminal of the AC power inlet Connect one of the test lead...

Страница 28: ...ive ground wire from testing Check the appropriate safety standard to determine if this is the case 2 8 Preliminary Inspection Always inspect the following four points before testing Check that the te...

Страница 29: ...TOS6200 6210 3 1 Chapter 3 Part Names and Functions Gives the names and functions of switches keys indications connectors and other parts on the front and rear panels 3 3...

Страница 30: ...his switch is used to stop a test Press this switch to cancel a PASS FAIL or PROTECTION status Pressing this switch places the tester in ready status 3 START This switch is used to start a test Press...

Страница 31: ...he maximum input voltage between the SAMPLING terminals is 10 V AC DC or less Do not apply external voltage exceeding this limit 6 LCD Displays information including the range of set values and measur...

Страница 32: ...fset measurement screen OFFSET 12 MEMORY RECALL STORE key Press this key to recall panel memory Change the memory number using the rotary knob then press the ENTER key next to this key This recalls th...

Страница 33: ...forward NEXT 16 Indicators TEST This LED indicates that testing is underway Blinks for contact checks when the contact check is set to ON standby PASS This LED gives the test result When the test resu...

Страница 34: ...tion regarding grounding see 2 6 Grounding 21 Handle Used to carry the tester 22 SIGNAL I O This D sub 25 pin connector is used for remote control of testing start and stop operations or to check the...

Страница 35: ...anels and fan exhaust port to allow sufficient air flow 26 Cord holders Used to wind the AC power cord when the tester is not in use Never use the tester in an upright position Use of the product with...

Страница 36: ...3 8 TOS6200 6210...

Страница 37: ...TOS6200 6210 4 1 Chapter 4 Basic Operation Describes basic operations such as setting test conditions and starting a test 4 4...

Страница 38: ...t displays the ROM version and other infor mation on the LCD the screen displayed when you last turned the POWER switch off appears When the switch is turned on for the rst time after pur chase the fo...

Страница 39: ...tly to a desired item Holding down with the SHIFT key press any of keys F1 to F5 to activate the operation indicated above the key Settings corresponding to safety standards At factory shipment settin...

Страница 40: ...OVER VA in 4 9 1 Setting Output out of the Operation Range OVER RESI blinks on the LCD TOS6210 only A value obtained by dividing the upper reference value by the test current value has exceeded 0 6 Te...

Страница 41: ...d judgment or sampled voltage value based judgment Press the SHIFT and F4 keys together to switch between judgment methods Each time you press the SHIFT and F4 keys the upper reference value alternate...

Страница 42: ...is case increase the upper reference value or reduce the lower reference value OVER VOLT blinks on the LCD A value obtained by multiplying the test current value by the upper reference value has excee...

Страница 43: ...ncrease the upper reference value or reduce the lower reference value OVER VA blinks on the LCD The setting has exceeded the maximum rated output Test cannot begin under the current conditions Change...

Страница 44: ...of the judgment method TOS6210 only The TOS6210 allows you to select resistance value based judgment or sampled voltage value based judgment Press the SHIFT and F4 keys together to switch between judg...

Страница 45: ...nce value Sampled voltage value based judgment TOS6210 only Set the lower reference value in the range of 0 01 V to 5 40 V resolution 0 01 V 1 Press the F2 LOWER key if the lower reference value is no...

Страница 46: ...ggles between ON and OFF You can also use the keys to move the cursor to the timer function ON OFF indicator With the cursor at the TIMER indication use the rotary knob to set Turning the knob clockwi...

Страница 47: ...nd OFF You can also use the keys to move the cursor to the offset function ON OFF indicator With the cursor at the OFFSET indication use the rotary knob to set Turning the knob clockwise ON Turning th...

Страница 48: ...ile holding down the SHIFT key To adjust OFFSET TOS6210 only A measured OFFSET value can be nely adjusted using either the SHIFT and F2 ADJ keys or the SHIFT and F3 ADJ keys together OVER VOLT blinks...

Страница 49: ...ormation on MOMENTARY see 4 4 System Setup 4 3 1 Starting a Test To begin the test To begin testing press the START switch while the MAIN screen indicates ready In the ready status the upper right par...

Страница 50: ...as pressed The tester has entered protection status PASS judgment When the lower limit judgment function is ON and the measured value falls between the upper and lower reference values the tester retu...

Страница 51: ...range between the upper and lower reference values the tester returns a FAIL judg ment When the lower limit judgment function is OFF the tester returns a FAIL for the measured value if the value exce...

Страница 52: ...l measurement mode MAX Retains a peak value 1 Press the F1 MEAS key or use the keys to move the cursor to MEAS MODE 2 Use the rotary knob to select either MAX or NORM Turning the knob clockwise MAX Tu...

Страница 53: ...val has been set to HOLD for pro grammed automatic testing the program cannot proceed to the next step ON OFF for Fail Mode With FAIL MODE set to ON FAIL judgment and protection status cannot be can c...

Страница 54: ...he DUT and causes current to ow the TEST LED on the panel lights and the tester begins test ing continuing the test until the set time elapses or the STOP switch is pressed Pressing the SHIFT and F4 k...

Страница 55: ...to move the cur sor to CONTRAST 3 Use the rotary knob to set contrast You can set contrast with the SHIFT key combination pressing the or key with the SHIFT key held down in any screen Entering Comme...

Страница 56: ...screen GPIB address RS 232C protocol Communication rate Data length Parity bit Stop bit 4 5 1 GPIB Address Set the GPIB address of the tester in the range from 0 to 30 The GPIB address set is not effe...

Страница 57: ...om the following two choices 7 bit 8 bit 1 Press the F3 DATA key or use the keys to move the cursor to DATA 2 Use the rotary knob to select either 7 or 8 Setting the Parity Bit Select a parity bit fro...

Страница 58: ...memory number then enter the name as shown below Moving the cursor to the memory number after setting a name restores the entered name to the previous name 1 Press the MAIN key to display the MAIN sc...

Страница 59: ...ary knob to specify the memory number to be recalled 00 to 99 3 Press the ENTER key This recalls the test conditions for that memory number Moving the cursor to another area of the screen before press...

Страница 60: ...a test of memory 01 in step 00 and then that of memory 02 in step 01 9 9 seconds after that Because the interval time of step 01 is set to HOLD the test of memory 3 in step 02 does not start unless yo...

Страница 61: ...mber step setting Interval time Repeat setting Setting a Program Name Enter the name of a program to create up to 12 characters as follows 1 Press the SHIFT F1 key combination pressing the F1 key with...

Страница 62: ...INS key to add the step MEM00 1 0s is added to the end of the list 4 Press the key to move the cursor to MEM to the right of the step number 5 Use the rotary knob to set a memory number 6 Use the key...

Страница 63: ...step will be displayed in reverse video 4 7 4 Suspending the Program Press the STOP switch to halt testing during program execution Press the START switch again to run the program from the beginning 4...

Страница 64: ...you that testing cannot be conducted unless it is changed The following four causes are displayed TOS6210 only 4 9 1 Setting Output out of the Operation Range The testers meet the following test curre...

Страница 65: ...VER VA If a setting meeting the following equation setting exceeding the operation range is made the READY indication in the upper right of the LCD changes to blink OVER VA informing you that testing...

Страница 66: ...that the setting falls within the operation range If a resistance value is set to the upper reference value OVER RESI check is not made 4 9 2 Upper Reference Value Lower Reference Value UP LOW If a lo...

Страница 67: ...nd the OVER HEAT indication blinks on the LCD stop testing for approximately the pause time speci ed in the table below and then press the STOP key If the output section temperature has returned to th...

Страница 68: ...5 4 V or less and a test can be performed the overload protection function is tripped if the output power exceeds the following maximum rated output during testing This causes the OVER LOAD indication...

Страница 69: ...ample assume that the DUT with 0 190 is tested with the test current set to 25 A and upper reference value set to 0 200 If the leads connected to the DUT are long and four terminal measurements are ma...

Страница 70: ...ress the SHIFT key until the characters KIKUSUI ELECTRONICS CORP disappear Factory shipped settings TOS6200 TOS6210 Test conditions set up screen MAIN Test current CURRENT 3 0 A 6 0 A Frequency FREQ 5...

Страница 71: ...TOS6200 6210 5 1 Chapter 5 REMOTE and SIGNAL I O Describes the REMOTE terminal for connecting optional equipment and the SIGNAL I O connector for input output signals 5 5...

Страница 72: ...on the front panel This connector is used to connect the optional RC01 TOS or RC02 TOS remote control boxes or the LP01 TOS or LP02 TOS test probe When you connect an option the START and STOP switch...

Страница 73: ...panel used to control testing start and stop or to monitor the status of the tester Fig 5 2 SIGNAL I O Connector Connector on the tester side Omron Corp XM3B 2522 D SUB 25 pin female connector Screw...

Страница 74: ...ltage 30 V DC Output saturation voltage Approximately 1 1 V at 25 C Maximum output current 400 mA total Pin configuration Fig 5 3 SIGNAL I O Pin Configuration To avoid damage to internal circuits take...

Страница 75: ...uring test not including the period of a current voltage rise 16 PASS O ON for approximately 0 2s or more when a measured value is judged PASS It is continuously ON when PASS HOLD is set to ON 17 UPPE...

Страница 76: ...f 10 ms or more from the READY signal has turned to a low level set the START signal to a low level for 5 ms or more The READY signal turns to a high level after the effective START signal has been de...

Страница 77: ...2 PM Signals and Panel Memory or Program Number to be Recalled MSD LSD MAIN AUTO PM7 PM6 PM5 PM4 PM3 PM2 PM1 PM0 H H H H H H H H Recalls panel memory 0 Recalls program 0 H H H H H H H L Recalls panel...

Страница 78: ...ransistors instead of a switch in the above example Con gure the circuit so that a collector current ic of 5 mA or greater passes through the transistor Output signal Example of driving a relay This e...

Страница 79: ...device messages used to create a program for remote control of the tester via GPIB or RS 232C To avoid electric shocks always turn off the power supply of the related equipment when connecting or disc...

Страница 80: ...kusui distributor agent GPIB cable 1 m code 92080 GPIB cable 2 m code 92070 GPIB cable 4 m code 92090 6 1 2 RS 232C Interface To use the RS 232C interface make the following settings For settings see...

Страница 81: ...inal ready 5 GND Signal ground 6 DSR Data set ready 7 RTS Request to send 8 CTS Clear to send 9 RI Ring indicator Controller side 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 D sub pin 9 female D sub pin 9 fem...

Страница 82: ...troller to the device and responses sent from the device to the controller Each message consists of a message header and data sections Command Commands include settings and queries Setting Used to exe...

Страница 83: ...d However in the event of a message terminator with only EOI use Acknowledgment messages RS 232C The acknowledgment message is peculiar to the RS 232C interface This message is sent from the tester to...

Страница 84: ...aracter string within these brackets represents program data Do not use these brackets when writing comments Characters or numbers separated by within these brackets indi cate that you can choose betw...

Страница 85: ...eneral purpose device messages used to specify of a terminator and other items CLS Clears of the status byte register event status register device status register protec tion register fail register in...

Страница 86: ...reset each bit of the service request enable register Also used to inquire about the contents of the service request enable register For details on the service request enable register see 6 4 Register...

Страница 87: ...age DCL or SDC has been received Also used to perform the same processing as is performed by a DCL message from the RS 232C Message Set value CLR DSE Used to set or reset each bit of the device status...

Страница 88: ...f 1 is returned Example When a test is being made A value of 12 is returned 4 Test 8 Test on Example When contact check is ON A value of 8 is returned ERR Used to inquire about the contents of the err...

Страница 89: ...the invalid setting register For details on the invalid setting register see 6 4 Registers Message Query INV Response Returns the contents of the invalid setting register to INV Example If Bit 0 OVER...

Страница 90: ...ual for your PC Message Setting SIL 0 1 Query SIL Program data Set value 0 Return an acknowledgement message 1 Do not return an acknowledgement mes sage default Response The set value for the SILENT m...

Страница 91: ...s to be set on the tester SYS TEM screen BUZZERVOL BVOL Sets or inquires about the buzzer volume Message Setting BVOL NR1 Query BVOL Program data Set value 1 to 10 default is 4 Resolution 1 Example BV...

Страница 92: ...20 characters then returns this as the result Example If KIKUSUI is entered in the 1st line no data is entered in the 2nd line and 123456789ABCDEFGHIJK is in the 3rd line the response message returns...

Страница 93: ...st in response to CON Example When contrast is set to 3 A value of 3 is returned DOUBLEACTION DAC Sets ON OFF for start double action or inquires about ON OFF status Message Setting DAC 0 1 OFF ON Que...

Страница 94: ...us of the fail mode in response to FMOD Example When fail mode is ON A value of 1 is returned MEASMODE MMOD Sets or inquires about the measurement mode Message Setting MMOD NORM MAX Query MMOD Program...

Страница 95: ...ON Momentary ON Response Returns the ON OFF status of the momentary in response to MOM Example When the momentary is ON A value of 1 is returned PASSHOLD PHOL Sets the PASS hold time or inquires about...

Страница 96: ...Change the set ting referring to OVER VOLT in 4 9 1 Setting Output out of the Operation Range OVER VA blinks on the LCD The setting has exceeded the maximum rated output Test cannot begin under the c...

Страница 97: ...s the set value of test frequency in response to FREQ Example When the test frequency is 50 Hz A value of 50 is returned RJUDGE RJUD TOS6210 only Sets ON OFF of resistance value based judgment or inqu...

Страница 98: ...ts a resistance value based lower reference value and ON OFF of the lower limit judgment function or inquires about the ON OFF status of the lower limit judgment function When you perform sampled volt...

Страница 99: ...e of this setting command causes sampled voltage value based judgment to be automatically selected Message Setting VLOW NR2 0 1 OFF ON Query VLOW Program data NR2 Lower reference value Set value 0 01...

Страница 100: ...t of the LCD changes to blink UP LOW informing you that testing cannot begin under the current conditions In this case increase the upper reference value or reduce the lower reference value OVER VOLT...

Страница 101: ...s to blink UP LOW informing you that testing cannot begin under the current conditions In this case increase the upper reference value or reduce the lower reference value OVER VA blinks on the LCD The...

Страница 102: ...e and the timer ON OFF setting Message Setting TIM timer 0 1 OFF ON Query TIM Program data timer NR2 Test time Set value 0 3 to 999 default is 1 0 Resolution 0 3 to 99 9 0 1 100 to 999 1 Unit s Progra...

Страница 103: ...suspended due to a HOLD setting in the interval to the next step This command message is valid only in the test conditions set up MAIN offset measurement OFFSET or program AUTO screens Switch screens...

Страница 104: ...screen SYSTEM1 4 Offset screen OFFSET 5 Those other than 1 to 4 above not avail able Response Returns the current mode displayed screen in response to FUN Example When the current mode displayed scree...

Страница 105: ...ice status register TEST and TEST ON bit 2 3 are 1 measured voltage value 4 50 V measured current value 25 0 A maxi mum measured resistance value 0 182 measured resistance value 0 180 and elapsed time...

Страница 106: ...if the timer is OFF or the remaining time if the timer is ON Message Query TIME Response Returns the elapsed or remaining time of the test in response to TIME Example When the timer function is ON and...

Страница 107: ...EM memory no Program data Sets the memory contents in the following order All parameters must be entered even when the lower limit judgment is set to OFF Enter any value into the lower reference value...

Страница 108: ...ry To inquire about the memory contents set using VMEM use MEMORY MEM In this case the voltage value is returned to the upper and lower refer ence values Messages Setting VMEM memory no memory name te...

Страница 109: ...y contents in response to MEM memory no Example When memory contents 10 is memory name TEST1 test current 62 0 A upper reference value 5 4 V lower reference value 0 05 V test time 999 s test frequency...

Страница 110: ...p number NR1 Set value 0 to 99 Resolution 1 Example To delete step 10 in program number 1 PDEL 1 10 PRGEDIT PED Overwrites a currently set step with a new step adds a step in a program or inquires abo...

Страница 111: ...n response to PED program number step number Example When PED 5 1 inquires about the contents of step 1 in program 5 and step 1 is con gured as memory 11 and an interval time of 5 seconds A value of t...

Страница 112: ...e of TEST1 to program number 1 PNAM 1 TEST1 Response Returns the name of the program in response to PNAM program number Example When program 1 named TEST1 is inquired about with a PNAM 1 A value of th...

Страница 113: ...of the 1 is returned PRGTEST PTES Recalls program contents Message Setting PTES NR1 Program data Set value 0 to 99 Resolution 1 PRGTOTAL PTOT Inquires about the number of steps corresponding to the p...

Страница 114: ...DSE Read using ESR Status byte register 7 6 7 6 CME EXE 3 2 1 0 3 2 1 0 3 2 1 0 TEST ON TEST FAIL STOP PROT PASS READY INV SET Protection register Invalid setting register Read using PROT Read using...

Страница 115: ...ndicats that a bit of the event status register has been set 4 DSB Device Status Bit Indicats that a bit of the device status register has been set 3 Not used in the tester 2 Not used in the tester 1...

Страница 116: ...only Bit Descriiption 7 Not used in the tester 6 Not used in the tester 5 CURR Current Error 1 When output current is more than 10 of the set value for current 4 REN Remote Enable Change in the ENABLE...

Страница 117: ...tester 4 Not used in the tester 3 OVER RESI Over Resistance Indicates that the setting exceeds the resistance measurement range 2 OVER VA Over Volt Amp Indicates that setting exceeds the power limit...

Страница 118: ...BVOL 1 to 10 1 Setting for the buzzer volume 9 BUZZERVOL BVOL Returns the value set for the buzzer volume 10 CLR Clears the input buffer and has it wait for a device mes sage Equivalent to DCL and SD...

Страница 119: ...mit judg ment function 36 MEASMODE MMOD NORM MAX Setting for the measurement mode 37 MEASMODE MMOD Returns the setting status of the measured result indica tion 38 MEMORY MEM 0 to 99 1 Memory number 2...

Страница 120: ...to 99 1 Program number 0 to 99 1 Step number 0 to 99 1 Memory number 0 to 9 9 HOLD 0 1 s Interval time up to the next step 49 PRGEDIT PED 0 to 99 1 Program number 0 to 99 1 Step number Returns the con...

Страница 121: ...Resolution 0 1 for 0 3 to 99 9 1 for 100 to 999 0 1 OFF ON ON OFF for the timer function 70 TIMER TIM Returns the test time and the ON OFF status for the timer function 71 TRM 0 to 3 1 Setting for res...

Страница 122: ...rence value 0 3 to 999 0 1 1 s Test time Resolution 0 1 when the set value is 0 3 to 99 9 1 when the set value is 100 to 999 50 60 Hz Frequency 0 1 OFF ON ON OFF of lower limit judgment 0 1 OFF ON ON...

Страница 123: ...copy of VISA library KI VISA This library can be downloaded from the Kikusui website http www kikusui co jp It is recommended that the TOS6200 6210 ActiveX driver also be downloaded Note that the samp...

Страница 124: ...onst LOWER_FAIL 2 Const UPPER_FAIL 4 Definition of the fail register Const OHP 1 Const OHTP 2 Const OVLD 4 Const VL 8 Definition of the protection Const REN 16 register Dim r As Long c As Long Dim str...

Страница 125: ...viRead tos strRdBack 255 c register to determine which reference value was violated If Val strRdBack LOWER_FAIL Then MsgBox LOWER FAIL Result Displays the LOWER FAIL test result If Val strRdBack UPPER...

Страница 126: ...ASRL_STOP_TWO vs viSetAttribute tos VI_ATTR_ASRL_FLOW_CNTRL VI_ASRL_FLOW_XON_XOFF End If Dim r As Long Dim strCommand As String Device Clear Device clear vs viClear tos Device clear performed when usi...

Страница 127: ...ores MEM20 MEM21 and strCommand PRGEDIT 10 1 21 1 5 vbCrLf vs viWrite tos strCommand Len strCommand r MEM22 into the 10th strCommand PRGEDIT 10 2 22 2 5 vbCrLf vs viWrite tos strCommand Len strCommand...

Страница 128: ...1 Const DSR_INVSET 2 Const DSR_TEST 4 Const DSR_TESTON 8 Definition of the device status register Const DSR_PASS 16 Const DSR_FAIL 32 Const DSR_STOP 64 Const DSR_PROTECTION 128 Const LOWER_FAIL 2 Cons...

Страница 129: ...olated If Val strRdBack LOWER_FAIL Then MsgBox LOWER FAIL Result Displays the LOWER FAIL test result If Val strRdBack UPPER_FAIL Then MsgBox UPPER FAIL Result Displays the UPPER FAIL test result Case...

Страница 130: ...6 52 TOS6200 6210...

Страница 131: ...S6200 6210 7 1 Chapter 7 Maintenance Explains tester maintenance and inspection of the tester To maintain high performance for an extended period perform maintenance and inspect the tester regularly 7...

Страница 132: ...oration or erase printed characters clouded display and so on 7 2 Inspection Any break or cracking in the covering greatly increases the risk of electric shock or fires If you find any breaks or crack...

Страница 133: ...h and unplug the AC power cord from the electrical outlet 2 Disconnect the AC power cord from the AC LINE connector on the rear panel 3 Use a screwdriver to remove the fuse holder as shown in Fig 7 1...

Страница 134: ...e condi tions However we recommend replacing the fan roughly every 60 000 hours We also recommend regular internal inspections and cleaning at the same interval Backup battery The tester uses a lithiu...

Страница 135: ...GNAL I O 5 1 Check that the tester is not in PROTEC TION PASS or FAIL status 4 10 Protection Fuction 4 31 Check that the tester is not in the midst of system setup interface setup or pro gram editing...

Страница 136: ...7 6 TOS6200 6210...

Страница 137: ...Unless otherwise speci ed the speci cations contained in this chapter are based on the following settings and conditions Warm up time 30 minutes Temperature 5 C to 35 C Humidity 20 to 80 R H no conden...

Страница 138: ...6 00 V AC Resolution 0 01 V Offset cancel function Not provided 0 00 to 5 40 V Offset ON OFF function provided Accuracy 1 of reading 0 02 V Response Mean value response rms value display response time...

Страница 139: ...o 5 40 V Resolution 0 01 V Judgment accuracy 2 of setting 0 05 V Calibration Calibration is performed with the rms value of the sine wave using a pure resis tance load LED PASS Lights for approximatel...

Страница 140: ...ctions except for the POWER switch and KEY LOCK function may be controlled remotely Baud rate 9600 19200 or 38400 bps GPIB Complies with IEEE Std 488 1978 Function All functions except for the POWER s...

Страница 141: ...d and judged FAIL 18 L FAIL O Continuously ON if a measured value equal to or below the lower reference value is detected and judged FAIL 19 READY O ON while the tester is in ready status 20 PROTECTIO...

Страница 142: ...del 450 VA max 100 V 200 V model 330 VA max 420 VA max Allowable frequency range 47Hz to 63Hz Insulation resistance 30M min 500 V DC between AC line and chassis Withstanding voltage 1390 V AC 2 second...

Страница 143: ...mensions Weight Approx 9 kg 19 84 lbs Approx 11 kg 24 25 lbs Accessories AC power cord 1 piece Test leadwire TL11 TOS 1 set TL12 TOS 1 set Short bar 2 pieces These are inserted between the OUTPUT and...

Страница 144: ...ensions Fig 8 2 TOS6210 external dimensions MAX345 13 58 35 1 4 MAX 270 10 63 MAX455 17 91 MAX10 0 39 430 16 93 MAX15 0 59 88 3 46 MAX140 5 51 Unit mm inch 430 16 93 MAX 10 0 39 MAX455 17 91 88 3 46 M...

Страница 145: ...nse to output This compact lightweight PWM sine wave inverter is capable of a maximum out put of 150 VA TOS6200 220 VA TOS6210 achieving a power conversion ef ciency of 90 3 Output transformer This st...

Страница 146: ...trol circuit Sends the detected output voltage to the power ampli er circuit for constant voltage at the output terminals It also DC converts the detected output voltage and displays averaged data as...

Страница 147: ...EC60065 1 25 A 0 1 0 001 60 s 50 Hz 0 0 1 2 4 IEC60065 2 10 A 0 1 0 001 1 s 50 Hz 0 0 1 3 5 IEC60065 3 10 A 0 2 0 001 1 s 50 Hz 0 0 1 4 6 IEC60204 1 10 A 0 1 0 001 10 s 50 Hz 0 0 1 5 7 IEC60335 1 25 A...

Страница 148: ...ve grounding pin IEC 60601 1 1995 Medical electrical equipment Part 1 General requirements for safety No distinction Between all accessible conduct ing parts of class I devices requiring grounding Pro...

Страница 149: ...probe and a metal part 1 25 A 50 or 60 Hz or 2 1 5 times the rated device cur rent whichever is greater 0 1 or less 5 to 10 sec The no load voltage must be 6 V or less 1 5 times the current capacity o...

Страница 150: ...ve conductor terminal or pro tective grounding pin UL2601 1 1997 Medical Electrical Equipment Part 1 General Requirement for Safety No distinction Between accessible metal parts of class I devices Pro...

Страница 151: ...oltage should be 12 V or less In measurements of resistance do not include the value for the AC power cord s protective grounding wire Exercise care so that the test results are not affected by the co...

Страница 152: ...power cord JIS T 1022 1996 Safety Requirements of Electrical Installations for Medically Used Rooms in Hospitals and Clinics Between a grounding pin receiver of medical electrical outlet or ter minal...

Страница 153: ...ance value For measurement conductors use conductors with a sectional area of 3 5 mm2 or greater make them as short as possible For connections between the measuring circuit accessible metal parts and...

Страница 154: ...A 10 TOS6200 6210...

Страница 155: ...ouble Action 4 18 E Ending the test 4 14 Excerpts from the safety standards A 4 F FAIL judgment 4 15 4 27 Fail Mode 4 17 Fan 3 7 7 4 Feet 3 3 Firmware version 1 2 Firmware version of products applied...

Страница 156: ...am screen 4 25 Protection fuction 4 31 Protection status 4 31 R RC01 TOS 1 5 1 6 RC02 TOS 1 5 Ready status 4 13 Rear panel 3 6 Recalling a panel memory and program 5 7 Recalling the memory 4 23 Recall...

Страница 157: ...TOS6200 6210 Index I 3 Turning on the power 4 2 U Unpacking 2 2 Upper reference value 4 5 UP LOW 4 30 V VOLT LIMIT 4 33...

Отзывы: