PWX
45
CONFIG Settings
Basic Functions
2
3
Press SET, which is blinking, again.
While the parameter number and the setting are blinking, no new settings will be
applied until you press SET.
When setting CF00, the measured value display appears.
When CF40 is set, the LAN LED lights in orange (for about 4 to 5 seconds) while the
setting is being confirmed and then turns green when it is complete. Press SET to exit
the CONFIG settings. The settings will be applied.
If the LAN LED turns red, set the settings again.
CONFIG parameter details
The CONFIG parameters are explained in detail below.
CF00 Resets the panel settings
Communication
Interface Manual
Sets whether the panel settings will be reset. The following settings will be reset. When the
settings are reset, the PWX series settings take on the same values as they do when an
*RST command is received.
You can only specify this parameter when the PWX series is being used as a master unit
.
• Output voltage
• Output on/off at power-on
• Output current
• Constant current control using an
Vext or Rext
(CF05)
• Overvoltage protection
• Constant voltage control using an
Vext or Rext
(CF06)
• Overcurrent protection
• External control setting for turning output on and off (CF09)
• Undervoltage limit
• Voltage and current setting limits (CF15 and CF14)
CF01 Master-slave parallel operation parameter
Sets the total number of units (master unit and slave units) in master-slave parallel operation.
Specify “SLAV” for the units that you want to use as slaves.
This parameter is applied when you turn the POWER switch off and on.
Changing this setting may affect the settings of the master unit or the slave units that are con-
nected in parallel.
Memo
Press any key other than
SET to cancel the
confirmation of the
parameter.
See
See
Value
Parameter description
rSt
Resets the panel settings
See
See
Value
Parameter description
SLAV
Use the PWX as a slave unit.
1 to 4
Set the total number of units (1 to 4; 1 indicates independent operation--factory
default setting).
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...