42
PWX
CONFIG Settings
Use the CONFIG settings to set the PWX series system configuration. You can set and dis-
play the following parameters in the CONFIG settings. The CONFIG parameters are listed in
a separate document (included with this manual).
Effects:
●
indicates a parameter that may be affected when the panel settings are reset (CF00) or when a
preset memory entry is loaded.
▼
indicates a parameter that may be affected when the master unit, the slave unit, or the number
of units is changed (CF01).
■
indicates a parameter that may be affected when the LAN interface settings are reset (CF40:
LCi/dEF).
In the “Note” column, “A” indicates a parameter that is applied immediately, “B” indicates a parameter
that is applied when the PWX series is turned on, and “C” indicates a parameter that is applied when
CF40 “APPL” is executed.
Parameter number,
CF (CONFIG)
+ a two-digit number
Setting display
Lit
CONFIG setting and
display examples
Display
switching
Parameter
number
Setting or display description
Effect Note
SYSTEM
CF00
1
Resets the panel settings
—
A
CF01
Master-slave parallel operation parameter
▼
B
CF02
Power-on status parameter
—
B
CF03
Method for clearing OHP, FAN, and AC-FAIL alarms
—
B
CF04
Memory content display parameter
—
A
CF05
CC control using an Vext or Rext
●
A
CF06
CV control using an Vext or Rext
●
A
CF07
CV/CC control range parameter
—
A
CF08
Range during voltage and current monitoring
—
A
CF09
External control parameter for turning output on and off
●
▼
A
CF10
External control logic parameter for turning output on and off
▼
A
CF11
Bleeder on/off parameter
—
A
CF12
Output-on startup state parameter
▼
A
CF13
Detection time of OCP activation
—
A
CF14
Current setting limit
●
▼
A
CF15
Voltage setting limit
●
▼
A
CF16
Panel display brightness setting
—
A
CF17
Communication monitor timer setting
—
A
CF18
2
Internal resistance setting
▼
A
CF19
3
Current and power display on slave units for master-slave parallel
operation
—
A
INTER-
FACE
CF20
LAN interface parameter
▼
■
4
B
CF21
Command language parameter
▼
B
CF22
Emulation parameter during remote control
▼
B
CF23
SCPI communication error display parameter
▼
A
CF24
Multichannel (VMCB) domain number parameter
▼
■
B or C
CF25
Multichannel (VMCB) channel number
▼
■
B or C
LAN
5
CF30
IP address display (1)
▼
─
CF31
IP address display (2)
▼
─
CF32
IP address display (3)
▼
─
CF33
IP address display (4)
▼
─
CF34
MAC address display (1) and (2)
▼
─
CF35
MAC address display (3) and (4)
▼
─
CF36
MAC address display (5) and (6)
▼
─
CF40
Resets (LCI/ DEF) or applies (APPL) the LAN interface settings
▼
A
CF41
IP address assignment method
▼
■
B or C
CF42
Manual IP address setting (1)
▼
■
B or C
CF43
Manual IP address setting (2)
▼
■
B or C
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...