SYSTem Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
SYST:CONF:MON:RANG
Sets the range for monitoring the voltage or current externally.
Command
SYSTem:CONFigure:MONitor:RANGe <character>
SYSTem:CONFigure:MONitor:RANGe?
Parameter
Value:
LOW
A range of 0 V to 5 V is used. (default)
HIGH
A range of 0 V to 10 V is used.
(Example)
SYST:CONF:MON:RANG HIGH
Response
Returns the range for voltage and current monitoring in character format in re-
sponse to SYST:CONF:MON:RANG?.
SYST:CONF:PROT:REC
Sets the output state when a low AC input protection (AC-FAIL) is released.
Command
SYSTem:CONFigure:PROTection:RECovery <character>
SYSTem:CONFigure:PROTection:RECovery?
Parameter
Value:
SAFE
Output is not turned on automatically. (default)
AUTO
Output is turned on automatically.
(Example)
SYST:CONF:PROT:REC SAFE
Response
Returns the output state when a low AC input protection is released in character
format in response to SYST:CONF:PROT:REC?.