PLZ-4W
Installation and Preparation 2-5
2.4
Connecting the Power Cord
The power cord that is provided varies depending on the destination for the product
at the factory-shipment.
• This product is designed to be connected to a power supply classi
fi
ed as
Overvoltage Category II. Do not connect to a power supply classi
fi
ed as
Overvoltage Category III or IV.
• The power cord for 100-V system shown in Fig. 2-2 has a rated voltage of
125 VAC. If this power cord is used at the line voltage of a 200-V system,
replace the power cord with that satisfying that line voltage.
Have a quali
fi
ed engineer select the appropriate power cord. If obtaining
the right power cord is dif
fi
cult, contact Kikusui distributor/agent.
•
Do not use the power cord that comes with the product as a power
cord for other equipment.
Fig. 2-2
Power cord with a three-pin plug
1.
Check that the AC power supply is within the input power supply range
of the product.
Input voltage range: 100 VAC to 240 VAC
(100 V to 120 V and 200 V to 240 V for the PLZ164WA
and PLZ664WA)
Frequency range:
47 Hz to 63 Hz
2.
Check that the POWER switch is turned off.
3.
Connect the power cord to the AC INPUT connector on the rear panel.
Use a power cord speci
fi
ed by Kikusui or one that has been selected by a qual-
i
fi
ed engineer.
4.
Insert the power plug to the outlet.
Power cord for 100-V system
Rated voltage: 125 VAC
Rated current: 10 A
Power cord for 200-V system
Rated voltage: 250 VAC
Rated current: 10 A
WARNING
[85-AA-0003]
PLUG:NEMA5-15
[85-AA-0005]
PLUG:CEE7/7
[85-10-0790]
PLUG:GB1002
Содержание PLZ-4W Series