A-6 Appendix
PLZ-U
TableA-3
Action taken when the OCP trips
A.2.3
Operation of the CV Mode
In CV mode, the PLZ-U supplies current so that the voltage at the load input end of
the PLZ-U is constant.
■
CV mode operation
When the PLZ-U is used in CV mode, the PLZ-U operates as a constant voltage
load (shunt regulator) as shown in Fig. A-7. When V1 is greater than V, the input
voltage V is kept constant even when the input current I varies. Current does not
fl
ow when V1 is less than or equal to V.
Fig. A-7
Equivalent circuit of the CV mode and operation
■
Transition of the operating point: Overpower protection (OPP)
We will consider the case when checking the load characteristics of the constant-
voltage power supply of Fig. A-7 using CV mode.
Fig. A-8
Transition of the operating point in CV mode (OPP trip point)
Point
F
Load-off function
on
Turns off the load (stops the current supply).
The PLZ-U no longer operates as a load.
Load-off function
off (limit)
CR mode ends. OCP continues, and the PLZ-U
supplies current as a constant current load.
0
I
V
R
1
V
Voltage is constant even when
the current changes
V
1
PLZ-U Series
Constant voltage
power supply
Input current I
Input voltage V
V
M
V
M0
V
N
V
M2
V
M1
Input voltage [V]
Input current [A]
Logarithmic scale
Constant power line
(OPP setting)
Constant voltage line
(Constant voltage setting)
Operating area
OPP trip point
M
N
I
N
I
OCP
M
1
M
2
Содержание PLZ-30F
Страница 32: ...2 18 Installation and Preparation PLZ U ...
Страница 58: ...4 14 Basic Operation PLZ U ...
Страница 144: ...6 52 Remote Control PLZ U ...
Страница 145: ...PLZ U Maintenance 7 1 Chapter 7 Maintenance This chapter explains the PLZ U maintenance 7 7 ...
Страница 186: ...A 26 Appendix PLZ U ...
Страница 190: ...I 4 Index PLZ U ...
Страница 191: ......