3

Specifications

Power requirement

Nominal Voltage

24 V AC/DC

Allowable voltage range

AC: 24 V± 10 %, DC: 20 V to 30 V

Current consumption 
(24 Vdc)

55 mA

Maximum power 

 

consumption

4 W

Installation location

Indoors at an altitude of up to 2 000 m

Environment

Operating

 

range

Temperature

0 °C 40 °C (32 °F to 104 °F)

Humidity

20 %rh to 80 %rh (No condensation)

Storage

 

range

Temperature

-20 °C to 70 °C (-4 °F to 158 °F)

Humidity

90 %rh or less (No condensation)

Safety

*1

*1.

A custom order model does not apply to.

Complies with the requirements of the following standard.

IEC61010-1:1990-09 / A2:1995-07

 

(Class lll, Pollution degree 2

*2

)

This equipment is designed to operate from overvoltage 
category I.

*2.

Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduc-              
tion of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-             
conductive pollution will occur except for an occasional temporary conductivity caused by

           

condensation.

Insulation resistance

30 M

Ω

 or more (500 Vdc) 

 

[between the connector and chassis]

Withstand voltage

500 Vac, 1 minute, 2 mA or less 

 

[between the connector and chassis]

Dimensions (largest section)

110 W x (160) H x 115 (120) D mm

 

(4.33 W x (6.30) H x 4.53 (4.72) D inch)

Weight

Approx.  700 g (1.54 Ib)

Accessories

Connection cord: 1 set (2.5 m)

 

Operation manual: 1 copy.

Содержание PL02-TOS

Страница 1: ...at blade screwdriver into A and open B 3 Insert the wire into B Take care to prevent the coating from becoming caught in B 4 Gently pull on the wire to confirm that it is securely connected OPERATION MANUAL Warning Light Unit PL02 TOS Part No Z1 002 690 IA002883 Dec 2018 WARNING Cover Illuminates or blinks in red when power is input BLINK ON OFF Switch used to select illuminating or blinking of th...

Страница 2: ...gnet is attached to the bottom of the PL02 TOS to fix it in place However do not place the PL02 TOS on a slanted surface uneven surface or a place with vibrations The rubber magnet cannot with stand strong shock Be careful not to drop the PL02 TOS by carrying out acts such as yanking on the con nection cord Such acts can damage the warning light If the cover needs cleaning gently wipe using a soft...

Страница 3: ...61010 1 1990 09 A2 1995 07 Class lll Pollution degree 2 2 This equipment is designed to operate from overvoltage category I 2 Pollution is addition of foreign matter solid liquid or gaseous that may produce a reduc tion of dielectric strength or surface resistivity Pollution Degree 2 assumes that only non conductive pollution will occur except for an occasional temporary conductivity caused by con...

Страница 4: ...CS CORP The newest version of the manual can be downloaded from Download service of Kikusui website www kikusui co jp en 2002 1 1 3 Higashiyamata Tsuzuki ku Yokohama 224 0023 Japan Tel 81 45 482 6353 Fax 81 45 482 6261 ...

Отзывы: