PFX2000
Setup 1-11
1.6
Installing and Removing Charge/Discharge
Power Supply Units
The charge/discharge power supply units can be installed or removed even if the
unit frame is rack mounted. Furthermore, if the charge/discharge power supply unit
is in the STANDBY status, you can install or remove the unit even if the power
switch of the unit frame is on. Consequently, if a charge/discharge power supply
unit malfunctions during a test, you can replace the unit without affecting the other
units.
1.6.1
Combinations of Unit Frames and Charge/Discharge
Power Supply Units
The unit frames and charge/power supply units can be combined as follows:
The two types of charge/discharge power supply units can be installed simulta-
neously to a single PFX2332.
PFX2011 5-V/5-A 2-ch
Charge/Discharge
Power Supply Unit
PFX2021 20-V/10-A
Charge/Discharge
Power Supply Unit
PFX2331 5-Unit Frame
Installable
Not installable
PFX2332 5-Unit Large Capac-
ity Frame
Installable
Installable