[SOURce:]FREQuency Command
PCR-WE Interface Manual
169
FREQ:TRIG
Sets the frequency to change to when INIT/INIT:TRAN or a software trigger is sent.
Command
[SOURce:]FREQuency:TRIGgered <numeric>
[SOURce:]FREQuency:TRIGgered?
Parameter
Value:
1.00 to 5000
Frequency (The default value is 50.0)
1.00 to 500.0 on the 500 Hz limit model
Unit:
HZ
Settings are reset to default values when an *RST command is sent.
Example
FREQ:TRIG 400
Response: NR3