Selecting an AC Signal (Internal Signal Source)
Start Phase and Square Wave Signal Duty Ratio (Page 2/5)
The PBZ uses the values that you specify for the settings that are explained in this section in
both bipolar mode and unipolar mode. The settable ranges are the same for both bipolar
mode and unipolar mode.
PHASE
Use the PHASE setting to set the AC signal start phase. If you have used
to set
OPERATION (synchronous operation) to SYNC SLAVE or SYNC SLAVE END, you cannot
set the start phase while the output is turned on (you can set it while the output is turned off).
●
Input range of the PHASE setting
DUTY
Use the DUTY setting to set the square wave signal duty ratio. You can specify this setting
when the AC signal waveform is set to
.
●
Input range of the DUTY setting
See
CV/CC mode
Input range
Resolution
Factory default setting
CV and CC
FREE (not specified)
–
0 deg
0 deg to 359 deg
1 deg
CV/CC mode
Signal frequency f
Input range
Resolution
Factory default setting
CV and CC
f < 100 Hz
0.1 to 99.9 %
0.1 %
50.0 %
100 Hz
f < 1 kHz
1 to 99 %
1 %
1 kHz
f < 10 kHz
10 to 90 %
10 %
10 kHz
f
50 % (fixed)
–
CONFIG
DUTY= t / T (%)
t
T
1/f
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...