4-
8
PAT-T 4kW
4.5
Using the PAT as a CV or CC Power Supply
(Setting the Output Voltage and Output
Current)
When using the PAT as a constant voltage power supply, the preset current is the
limit that can flow through the load.
When using the PAT as a constant current power supply, the preset voltage is the
limit that can be applied to the load.
If the specified limit is reached, the operation mode automatically switches. If the
operation mode switches, it is indicated by changing the LED of CV or CC.
•
When the phase input mode is changed to the single-phase input mode from the
three-phase input mode, the setting value of the output current and the
overcurrent protection (OCP) is limited to 75 % of the rated value of output
current and the overcurrent protection of the three-phase input mode.
1
T
u
rn the POWER s
w
itch off.
2
Connect the load to the o
u
tp
u
t terminal.
3
T
u
rn the POWER s
w
itch on.
If the OUTPUT LED on the display is illuminated, press the OUTPUT switch to turn
the output off.
4
Check that the SET key is ill
u
minated.
If it is not, press the SET key so that you can set the voltage and current.
5
T
u
rn the VOLTAGE knob to set the voltage.
6
T
u
rn the CURRE
N
T knob to set the c
u
rrent.
7
Press the OUTPUT s
w
itch.
The OUTPUT LED on the display illuminates, and the voltage and current are
delivered to the output terminal.
The CV LED illuminates when the PAT is operating as a constant voltage power
supply.
The CC LED illuminates when the PAT is operating as a constant current power
supply.
You can set the voltage and current by carrying out step 5 and step 6 while
checking the actual output voltage or current with the output turned on.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...