PAT-T 4kW
9-9
9
Spec
ifica
tions
General specifications
PAT20-200T
PAT40-100T
PAT60-67T
PAT160-25T
Weight
(main
u
nit only)
Approx. 20 kg
(Approx. 44 lbs.)
Approx. 19 kg
(Approx. 42 lbs.)
Approx. 1
8
kg
(Approx. 40 lbs.)
Dimensions
See the o
u
tline dra
w
ing
Environmental conditions
Operating conditions
Indoor
u
se, Overvoltage Category II
Operating temperat
u
re
0
°
C to +50
°
C
(+32
°
F to +122
°
F)
Operating h
u
midity
20 %rh to
8
5 %rh (no condensation)
Storage temperat
u
re
-25
°
C to +70
°
C
(-13
°
F to +15
8
°
F)
Storage h
u
midity
90 %rh or less (no condensation)
Altit
u
de
Up to 2 000 m (Approx. 6 560 ft)
Cooling system
Forced air cooling
u
sing a fan. (With fan control)
Gro
u
nding polarity
N
egative gro
u
nding or positive gro
u
nding possible.
Isolation voltage
±250 Vmax
±500 Vmax
Withstand voltage
Across the primary side of the
transformer and chassis
N
o abnormalities at 1 500 Vac for 1 min
u
te.
Across the primary and secondary
sides of the transformer
Across the secondary side of the
transformer and chassis
N
o abnormalities at 500 Vdc for 1 min
u
te.
Ins
u
lation resistance
Across the primary side of the
transformer and chassis
500 Vdc, 30 M
Ω
or more. (at a h
u
midity of 70 %rh or less)
Across the primary and secondary
sides of the transformer
Across the secondary side of the
transformer and chassis
Safety
*1
*1.
N
ot applicable to c
u
stom order models.
Complies
w
ith the req
u
irements of the follo
w
ing directives and standards
Lo
w
Voltage Directive 2006/95/EC
E
N
61010-1
Class I
Poll
u
tion degree 2
Electromagnetic Compatibility (EMC)
*1, *2
*2.
Applies only to models that have CE marking on the panel.
Complies
w
ith the req
u
irements of the follo
w
ing directives and standards.
EMC Directive 2004/10
8
/EC
E
N
61326-1
Applicable condition
All of the cables and
w
ires connected to the PAT
are less than 3 m in length.
Accessories
OUTPUT terminal cover
2 sets (
w
ith scre
w
s)
O
u
tp
u
t terminal bolt set
2 sets (M10
×
20 mm bolts, n
u
ts, and spring
w
ashers)
J1/J2 connector kit
1 set (2 sets of protection covers, 2 pl
u
gs, and 30 pins)
Chassis connection
w
ire
1 set (
w
ith scre
w
s)
Operation man
u
al
1 pc.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...