PAN-A
4-25
Chap
.4
Applied Oper
ation
1
• To minimize the in
fl
uence of noise on the output, use a 2-core
shielded wire or a twisted-pair wire to connect the control ter-
minals and the external contact points. If using a shielded
wire, connect the shield to the + (pos.) output terminal.
Note that longer lengths of wiring result in more susceptibil-
ity to the effects of noise; use of cables with anti-noise mea-
sures may not solve the problem.
• The control terminal [10] is "common" for the control circuit.
It is internally connected to +S on the unit.
• The release voltage across the control terminals [10] and [11]
is approx. 5 V, and the short circuit current is approx. 1.5 mA.
• Use external contact points of rated 10 VDC min. and 10 mA
min.
• For long-distance wiring, use a small relay and extend the coil
side of that relay.
4. Re-check that the connections on the terminal board and
the switch settings are correct.
Fig.4-16
Output ON/OFF control connection
NOTE
2
7
8
13
14
19
Rear OUTPUT terminal
board (PAN16-50A)
Rear CONTROL terminal board
Rear OUTPUT
terminal board
[11]
[10]
S
S
RL
2-core shielded wire
or twisted-pair wire
For long-distance wiring
Extend this line.