OT01-PCR-LA/2
Single-phase, Three-wire Operation 6-15
6.11.3 Output Measurement Messages
VOUT?
Inquires about a measured voltage value
Program message
• Syntax
Query message:
VOUT?
Response message
Returns U- and V-phase voltages, delimited by a comma (,), in the phase voltage
display mode; returns U-V voltage, in the line voltage display mode
IOUT?
Inquires about a measured current value
Program message
• Syntax
Query message:
IOUT?
Response message
Returns U- and V-phase currents, delimited by a comma (,)
WATT?
Inquires about a measured power value.
This message is enabled in the phase voltage display mode.
Program message
• Syntax
Query message:
WATT?
Example: A response message for VOUT? in the phase voltage display mode is
115.3,115.4
V-phase voltage
U-phase voltage
Example: A response message for VOUT? in the line voltage display mode is
200.0
U-to-V line voltage
Example: A response message for IOUT? is
10.0,10.1
V-phase voltage
U-phase voltage