6-4 Single-phase, Three-wire Operation
OT01-PCR-LA/2
6.4
Limit Value Setting
Voltage limit value setting
Voltage limit values can be set only on the U-phase unit. The limit values set on the
U-phase unit are valid for V phase. A voltage limit cannot be individually set for
each phase.
A voltage limit value is a limit on the phase voltage; a line voltage limit operates at
a value twice the phase voltage limit.
Frequency limit value setting
Frequency limit values can be set only on the U-phase unit. The limit values set on
the U-phase unit apply to V phase. A frequency limit cannot be individually set for
each phase.
Current limit value setting
A current limit value can be set for each phase.
6.5
Current/Power Display Mode
Each time the I MODE (SHIFT, I) key is pressed, the current/power display mode
changes as shown below.
If the output power exceeds 10 kW, “E3” appears at the upper left of the power dis-
play.
Display of the U-phase power supply
RMS (current)
PEAK (current)
W (U-phase power)
W (total power of
the two phases)
Display of the V-phase power supply
RMS (current)
PEAK (current)
W (V-phase power)
W (V-phase power)
Содержание OT01-PCR12000LA/2
Страница 10: ...VIII Contents OT01 PCR LA 2 ...
Страница 16: ...1 6 General OT01 PCR LA 2 ...
Страница 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Страница 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Страница 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Страница 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Страница 94: ...1 2 Index OT01 PCR LA 2 ...
Страница 95: ......
Страница 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...