OT01-PCR-LA/2
Single-phase Parallel Operation 5-5
• When requesting a repair, inform us of this number.
Check to be Performed if “Err X” is Displayed
If an error occurs, the control panel will continue displaying “Err X” (X: number).
If an Err display appears, always turn the POWER switch OFF and take steps in
accordance with Table 5-3.
Table 5-3
Err Numbers and Remedies (The section to be referred
to in the Remedy column indicates the section number
in the PCR-LA AC Power Supply Operation Manual.)
7
The sensing function has been used improperly.
See “4.5 Sensing
Function”.
8
The power unit concerned may have been removed. This alarm can be
cleared to use the system. However, the output capacity will be limited
due to the fact that the power unit is not functioning.
See Alarm-
clearing procedure (Alarm (8)).
Err X
Remedy
1
All internal power units are defective.
Immediately stop using the
AC power supply and contact your Kikusui distributor/agent.
2
An error has occurred in signal communication between the PCR-LA
power supplies or within a PCR-LA power supply.
Turn the SYSTEM
POWER switch OFF and wait for more than 5 seconds, then
turn the switch ON again.
If no Err occurs, the power supply can continue to be used.
If Err occurs again, contact your Kikusui distributor/agent.
4
An error has occurred in the AC power supply.
Turn the SYSTEM
POWER switch OFF and wait for more than 5 seconds, then
turn the switch ON with the MEM key held down. Then, per-
form a reset. This causes the power supply to enter the initial
setup status.
5
The input voltage is out of the rated range.
See “2.5 Input Connec-
tions”.
Other numbers
Contact your Kikusui distributor/agent.
NOTE
Содержание OT01-PCR12000LA/2
Страница 10: ...VIII Contents OT01 PCR LA 2 ...
Страница 16: ...1 6 General OT01 PCR LA 2 ...
Страница 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Страница 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Страница 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Страница 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Страница 94: ...1 2 Index OT01 PCR LA 2 ...
Страница 95: ......
Страница 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...