3-4 Output Switching
OT01-PCR-LA/2
5.
Turn the SYSTEM POWER switch ON.
This turns power to the entire system ON.
Turning the OUTPUT of the PCR-LA power supply (U-phase unit) ON
enables the supply of power to the load.
3.2
External Control
Using external contacts, the SYSTEM POWER switch can be turned ON/OFF and
the WIRING switch can be controlled. Even during external control, the switches
on the Output Terminal front panel are always enabled.
For external control, use the EXT CONT terminal.
■
Terminal names and numbers
■
Terminal functions
To turn the SYSTEM POWER switch OFF, short-circuit terminals numbers 1 and 2.
To turn the SYSTEM POWER switch ON, short-circuit terminals numbers 3 and 4.
To select 1P of the WIRING switch, short-circuit terminals numbers 5 and 6.
To select 1P3W of the WIRING switch, short-circuit terminals numbers 7 and 8.
■
Available wires
Single wire: Wire diameter of 0.32 mm (AWG28) to 0.65 mm (AWG22)
Twisted wire: Conductor cross-sectional area of 0.08 mm
2
(AWG28) to 0.32 mm
2
(AWG22)
Individual wire diameter: 0.125 mm or more
Wire peeling-off length: 9 mm to 10 mm
Terminal
number
1
2
3
4
5
6
7
8
Terminal
name
P-OFF+ P-OFF- P-ON+ P-ON-
1P+
1P-
1P3W+
1P3W-
Содержание OT01-PCR12000LA/2
Страница 10: ...VIII Contents OT01 PCR LA 2 ...
Страница 16: ...1 6 General OT01 PCR LA 2 ...
Страница 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Страница 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Страница 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Страница 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Страница 94: ...1 2 Index OT01 PCR LA 2 ...
Страница 95: ......
Страница 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...