20
LIN-JF
3
Wiring the Test System
This chapter describes how to wire the product to the test system.
Removing the Terminal Cover
Remove the terminal cover, and then connect the terminals. After connecting the terminals,
be sure to attach the terminal cover back on using the left and right screws.
1
Check that the POWER switch is turned off.
Check that the power indicator on the front panel is off.
2
Unfasten the screws from the terminal cover attached to the lower part
of the rear panel of this product.
Leave the cover open until all wiring is finished.
Connecting the Control Power Cable
1
Connect the supplied control power cable to the AC INPUT terminal on
the rear panel.
Connect the power wires from the power cable to the L and N terminals and the ground
wire to the protective conductor terminal.
2
Connect the control power cable plug to a properly grounded outlet.
The product can receive a nominal line voltage in the range of 100 Vac to 240 Vac at
50 Hz or 60 Hz.
WARNING
• Risk of electric shock. For the devices that will be used in the test circuit, be sure
to remove the power cable from the AC power line, turn off the switchboard that
the power cable is connected to, and turn off the POWER switch.