
13
KHA3000
337
Rem
ote Control
Status Registers and Status Report Function
The IEEE 488.2 register and SCPI register are used for status reports.
Each SCPI status register has the following subregisters: CONDition register, EVENt register,
ENABle register, PTRansition filter and NTRansition filter.
The figure on page 338 shows the SCPI status register structure.
“
+
”
indicates the logical
sum of register bits.
The tables on pages 339 to 343 provide a summary of bit numbers, bit weights and bit
meanings.
CONDition register
The bits of the CONDition register are automatically set to indicate the current status of this
product. Reading this register does not affect the register data.
EVENt register
The bits of the EVENt register are automatically set according to the changes in the
CONDition register. The rule varies depending on the positive transition or negative transition
registers (PTRansition and NTRansition). Reading the EVENt register clears the register
data.
ENABle register
The ENABle register enables reports to the summary bit and status bit of event bits.
Transition filters
The PTRansition (positive transition) filter can be used to report an event when the condition
has changed from false to true.
The NTRansition (negative transition) filter can be used to report an event when the state has
changed from true to false.
If both positive and negative filters are set to true, an event can be reported every time the
status changes.
If both filters are released, event reporting is disabled.
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......