25
JMNC Operating Instructions
6 Setting the Rotational Speed Monitoring Device JMNC
6 Setting the Rotational Speed Monitoring Device JMNC
Attention!
Only switch on the rotational speed monitor-
ing device together with the drive.
Only set the device with corresponding oper-
ating temperature in order to reach the high-
est accuracy when setting the switching
point.
When using the included setting tools (
22
) they
are latched and hard to pull off again. We there-
fore recommend you to leave the setting tools
(
22
) in order to prevent maladjustment of the po-
tentiometers when pulling the tools off.
It is also possible to use a screw driver with an
insulated shoe.
6.1
Before Setting the Device
The potentiometers start-up delay (
1
) and Fine (
3
) are
covered with plastic caps to protect them from contami-
nation
.
1. Remove the plastic caps from the potentiometers
start-up delay (
1
) and Fine (
3
).
2. Carefully plug the two setting tools (
22
) onto the po-
tentiometers.
Fig. 6-1: Using the setting tools
rotational speed monitoring device (
9
)
setting tools (
22
)