DG Operating Instructions

1  For Your Own Safety

1

For Your Own Safety

1.1

Intended Application

The pulse generators of the DG type series generate
pulses, the frequencies of which depend on the rotation-
al speed. The pulse generators are particularly suited for
application if high accuracy of operation, long service life
as well as wear and corrosion resistance are important.
The pulse generators meet the high requirements of the
relevant regulations.The device is intended for use in
stationary installations and in vehicles.
Applications other than specified and unauthorized mod-
ifications to the device or its components can lead to in-
jury to persons and damage to the device, for which the
manufacturer is 

not liable

.

Make sure that the intended use is not impaired in any
way, even after unexpected outside influence on the de-
vice.
"Intended application" particularly means that any work
performed with or on the device is to be carried out in
accordance with these 

operating instructions

. Only

skilled persons

 who are familiar with the 

Regulations

on the Prevention of Accidents

 as well as the other

generally accepted safety rules are allowed to work on
this device.

You protect yourself and prevent damage to the de-
vice when you apply the device as intended!

1.2

Symbols

Please pay particular attention to the text passages that
are marked with the following symbols:

Danger!
Information that has to be observed at all
events in order to protect the user from being
injured. 

Attention!
Information that has to be observed in order
to prevent damage to the device.

Helpful additional information

Содержание DG 10

Страница 1: ...OPERATING INSTRUCTIONS Pulse Generator Type DG ...

Страница 2: ...tions CE Sign and Conformity The device meets the requirements of the valid Europe an and national regulations Conformity has been proved and the corresponding dec larations and documents are deposited with the manu facturer ...

Страница 3: ...posal 6 2 1 Transport and Packing 6 2 2 Storage 6 2 3 Disposal 6 3 Design and Function 7 3 1 2 Wire Pulse Generator according to NAMUR EN 50227 7 3 2 PNP Switching 3 Wire Pulse Generator 7 4 Technical Data 8 4 1 General Technical Data 8 4 1 1 Standards and Regulations 8 4 1 2 Electrical Data 8 4 1 3 Mechanical Data 9 4 2 Dimensions 10 1 379 m 2 3 m 5 A 172 W 170 W ...

Страница 4: ...g Instructions Table of Contents 5 Mounting and Dismounting 11 5 1 Scope of Supply 11 5 2 Mounting 11 5 2 1 General Mounting Instructions 11 5 2 2 Mounting and Connecting the Pulse Generator 12 6 Ordering Devices 13 ...

Страница 5: ...manufacturer is not liable Make sure that the intended use is not impaired in any way even after unexpected outside influence on the de vice Intended application particularly means that any work performed with or on the device is to be carried out in accordance with these operating instructions Only skilled persons who are familiar with the Regulations on the Prevention of Accidents as well as the...

Страница 6: ...the device due to transport is prevented for which the manufactur er is not liable 2 2 Storage Avoid significant variations in temperature as this can lead to condensed water which might damage the de vice The permissible storage temperature is between 25 C and 70 C Attention Keep the device clean and dry 2 3 Disposal Reuse the packing material if possible or dispose of it in an environment friend...

Страница 7: ...ansis tor oscillator the high frequency stray field of which makes up the response zone When a metallic object is immersed into the effective area of the stray zone the resonant circuit is short circuited and its internal resist ance becomes high impedance The oscillations stop and the current consumption of the pulse generator de creases This current change is analysed by the rota tional speed mo...

Страница 8: ...81 2 Electromagnetic Compatibility EMC Generic Emission Standard 2 Industrial Environment EN 50082 2 Electromagnetic Compatibility EMC Generic Immunity Standard 2 Industrial Environment VDE 0110 pollution degree 3 Insulation Co ordination for Equipment within Low voltage Systems 2 wire pulse generator acc to NAMUR EN 50227 DG 5 DG 10 Rated operational voltage UB DC 8 2 V DC 8 2 V Internal resistan...

Страница 9: ...ent Ie 200 mA 200 mA Idle current I0 10 mA 10 mA Operating frequency 1 kHz 0 5 kHz Rated operating distance sn total tolerance zone 0 81 sn 1 21 sn dependent on the material of the actuating object 8 mm 10 mm Fitting flush flush Connecting lead 3 x 0 34 mm2 2 m long 3 x 0 34 mm2 2 m long 2 wire pulse generator acc to NAMUR EN 50227 DG 5 DG 10 Type Threaded pipe Housing diameter Tightening torque W...

Страница 10: ...o resistant to oil petrol and alkaline solutions 4 2 Dimensions Degree of protection acc to EN 60529 IP 67 Temperature range Standard DG 5 TN DG 10 TN DG 5 TH DG 10 TH 25 C 70 C 40 C 70 C 25 C 100 C Fig 4 1 Mounting dimensions DG 5 DG 10 DG 5 TH TN S DG 10 TH TN S DGP 5 DGP 10 ...

Страница 11: ... the head 4 of the pulse generator within the re sponse distance see fig 5 1 One pulse is generated per metal part Pulse multiplication via symmetrical ar rangement of several metal parts is recommended for low rotational speeds The metal parts should at least have the dimension of the head 4 of the pulse genera tor and the distance between any two parts should not be below the double diameter of ...

Страница 12: ...uctions in section 5 2 1 and the me chanical data in section 4 1 3 3 Connect the pulse generator in accordance with the wiring diagram see fig 5 1 Fig 5 2 Mounting the pulse generator Fig 5 1 Pulse generator of the DG type series BN BU BK pnp 1 BN 2 BU NAMUR head 4 of the pulse generator fixing nuts 1 Width of the weld on plate 3 30 mm Thickness of the weld on plate 3 7 mm 40 56 26 40 6 2 6 2 16 2...

Страница 13: ...tion number when you place a purchase order with Vossloh Kiepe GmbH see company address on back cover Type Device identification No DG 5 96 040 610 105 DG 5 TH 215 36 01 02 11 DG 5 TN 215 36 01 02 10 DGP 5 383 06 07 20 00 DG 10 96 040 610 110 DG 10 TH 215 36 01 02 16 DG 10 TN 215 36 01 02 15 DGP 10 383 06 07 03 00 DG 10 S 383 06 07 02 00 ...

Страница 14: ...14 DG Operating Instructions 6 Ordering Devices ...

Страница 15: ...15 DG Operating Instructions ...

Страница 16: ...on Index Copyright reserved Subject to changes 94 056 264 191 11 10 2006 D Distribution Swizterland APS systems AG Neumatt 4 Tel 41 0 62 517 88 33 4626 Niederbuchsiten Web www kiepe elektrik ch Switzerland Mail info kiepe elektrik ch ...

Отзывы: