Product Description

RPW414P-FTL room control module 

Room control module with room humidity/temperature sensor, SolarRadio

+

 

technology, integrated bidirectional EnOcean wireless interface and an 
algorithm for self-learning of utilization time profiles/heating profiles in rooms.

Application

Solar-powered, self-learning room control module with LCD and smart commu-
nication management.
For measuring room humidity and temperature, independent generation of utili-
zation time profiles and their continuous dynamic adjustment/optimization and 
for wireless transmission of measured values.
Operating elements for manually changing the comfort mode or economy mode 
status to adjust the room setpoint.
Together with the MD15-FTL wireless small actuator, the RPW414P-FTL room 
control module constitutes a functional unit for easy room temperature control.
The following EnOcean Equipment Profiles (EEP) are supported:

EEP D2-10-30 *

* You can find information about the protocol description on the EnOcean
   Technology website http://www.enocean-alliance.org/en/enocean_standard/

Содержание RPW414P-FTL

Страница 1: ...ce and an algorithm for self learning of utilization time profiles heating profiles in rooms Application Solar powered self learning room control module with LCD and smart commu nication management Fo...

Страница 2: ...hing in the MD15 FTL radio partner on the RPW414P FTL 13 Mounting 14 Removal 16 Operating level 16 Setting the initial display 16 Setting the setpoint 16 Manually switching between comfort and economy...

Страница 3: ...he applicable local regulations must be observed when installing and using the device Meaning of the symbols WARNING Indicates a hazard of medium risk which can result in death or severe bodily injury...

Страница 4: ...his device contains a humidity sensor This humidity sensor is influenced by chemical substances in the air that can be produced for example due to the evaporation of cleaning and care products used to...

Страница 5: ...er Integrated PIR Passive infrared sensor Integrated digital measuring transducer Measuring range Temperature Relative air humidity 0 50 C 20 80 Measuring tolerance Temperature Relative air humidity T...

Страница 6: ...the radio partner is interrupted an internal resynchronization algorithm starts automatically Radio interference is indicated on the screen by corresponding icons see page 28 CAUTION This product use...

Страница 7: ...ion shafts fire doors etc must be taken into consideration during planning CAUTION Elevated humidity increases natural signal damping NOTE Recommendation Plan radio paths horizontally on a single leve...

Страница 8: ...n of RPW414P FTL the selected installation location can be changed and optimized at any time without additional effort The installation location must have sufficient lighting using the device in unlit...

Страница 9: ...g To select the service level see page 25 06 Down arrow button To adjust reduce value 07 Selector button To select the display or menus 08 Occupancy button To switch between comfort mode economy mode...

Страница 10: ...ted presence absence and vacation mode 10 Auto Learned utilization time profile is active automatic mode 11 Bars Shows the field strength of the receiving wireless signal in infor mation menu only 12...

Страница 11: ...ting the installation location NOTE The Test installation location function remains active as long as the text InSt is displayed see page 12 The room control module switches off again if a radio partn...

Страница 12: ...If a radio partner has not been taught in after 15 minutes the room control module automatically switches off NOTE If the energy storage unit is empty the Sun icon will not appear even if the locatio...

Страница 13: ...seconds following completion of the teach in process Once all wireless small actuators have synchronized successfully after the teach in process the antenna symbol is also displayed after a further 4...

Страница 14: ...ope of delivery of the room control module WARNING Flush mounted cabling and piping at the installation location electricity gas water Cabling and piping can be damaged by drilling Check the installat...

Страница 15: ...ounting Flexible screw mounting 1 Bar 2 Adhesive numbers Wall mounting Flexible adhesive mounting with double sided transparent adhesive strips NOTE For a permanent connection remove any dust and grea...

Страница 16: ...hange the current setpoint manually Briefly press the or button The setpoint to be set flashes Set the required setpoint using the or button The new selected value flashes for approx 5 seconds It is t...

Страница 17: ...then active again and the Auto icon appears on the display Example 1 Comfort temperature 20 C economy temperature 16 C Room used 6 00 AM 9 00 AM and 3 00 PM 9 00 PM Absence set manually by pressing th...

Страница 18: ...sary to adequately ventilate the room To save on heating costs there is also an option to have the wireless small actuator close the valve Press and hold the button for 5 seconds The window icon appea...

Страница 19: ...repeatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds Release the Occupancy button The Set vacation menu item appears in the display Hold the Occupancy butt...

Страница 20: ...Briefly press the Occupancy button repeatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds The Set vacation menu item appears in the display Briefly press th...

Страница 21: ...European Time Setting the 12 24 hour display Hold down the Occupancy button for 5 seconds The text Menu briefly appears on the display followed by SETP Release the Occupancy button Briefly press the O...

Страница 22: ...peatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds The Set vacation menu item appears in the display Briefly press the Occupancy button repeatedly or the b...

Страница 23: ...other actions the display will return to the initial display after 5 seconds Status message The status message is displayed For more information see page 28 Display of the taught in radio partners If...

Страница 24: ...int comfort mode economy mode or vacation mode Comfort mode setpoint Briefly press the Occupancy button or the or button to set the required setpoint The setpoint for comfort mode continues to flash w...

Страница 25: ...y press the Setting button The room control module switches to the service level Briefly press the Occupancy button repeatedly or the button and the aforementioned functions will be offered one after...

Страница 26: ...ible to connect to a Building and Energy Management System BEMS This makes it possible to generate additional functions such as Visualizing operating states Displaying trend curves e g for the room te...

Страница 27: ...lt settings and switch off room control module function will run The room control module switches off The display disappears NOTE The taught in radio partners are then deleted and the room control mod...

Страница 28: ...mall actuators Antenna Er01 On On Radio connection partly interrupted 1 hour At least one wireless small actuator is transmitting Antenna Er01 Off On Radio connection interrupted 1 hour No wireless sm...

Страница 29: ...pear in the display more and more frequently it indicates that the AA lithium batteries need to be replaced This must be carried out by an authorized service technician Please contact your supplier Ra...

Страница 30: ...ion is detected in the room control module the Er08 icon appears on the display The following troubleshooting procedures can be implemented Reset the room control module to the factory settings see pa...

Страница 31: ...s monitored constantly If a system time malfunction is detected in the room control module the Er03 icon appears on the display Reset the time and date see page 20 The Er03 icon disappears from the di...

Страница 32: ...A Page 32 32 Product Description RPW414P FTL Datasheet 1 10 65 040 01 EN Issue 2017 04 10...