background image

A

Page 3 / 8

Datasheet 1.10-51.111-01-EN

DDC111, DDC111-2

Product Description

Issue 2012-05-09

Item

Technical Data

Accessories (not included in delivery)

DDC111-2

Room control module with LCD display for indication of room temperature, allows manual set-
ting of the room temperature setpoint and switching between three fan levels.

DDC111

Room control module with LCD display for indication of room temperature, allows manual set-
ting of the room temperature setpoint, switching between day, night and stand-by modes, and 
switching between three fan levels.

Measured variable

Room temperature of spaces in homes or commercial premises

Measuring system

Integrated digital room sensor

Measuring range

0 °

С

 to 45 °C

Connection

RJ socket

Display

LCD display:

Room temperature actual value 0.0 °C to 45.0 °C, in steps of 0.1 K

Room temperature setpoint, in steps of 0.1 K

Symbol display to indicate operating mode

Fan levels

DDC111-2 operating buttons

button: Switches to temperature mode for setting the room temperature 
setpoint
button: Switches to fan mode for setting the fan level

button: Sets the room temperature setpoint or allows manual setting of 
the fan level

DDC111 operating buttons

button: Switches to day mode

button: Switches to night mode or to stand-by mode

button: Switches to temperature mode for setting the room temperature 
setpoint
button: Switches to fan mode for setting the fan level

button: Sets the room temperature setpoint or allows manual setting of 
the fan level

Housing

Plastic housing, color RAL9010 (pure white), other colors available on request

Degree of protection

IP30

Ambient temperature

0 °C to 45 °C

Ambient humidity

Non-condensing

Installation

Flush-mounted box

Dimensions

WxHxD: 82.5 x 82.5 x 30.0 mm

Weight

110 g

Z178

Connection line: room control module <> room controller (RJ plug on both sides, 10 m)

Z178/2

Adapter: RJ plug - terminal block, 4-pole (15 cm)

Содержание DDC111

Страница 1: ...oom control modulel Application The room control modules are used together with the technolon RCNxxx L or FBR110 L room controllers A room control module can be connected to each technolon room contro...

Страница 2: ...perator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar...

Страница 3: ...t in steps of 0 1 K Symbol display to indicate operating mode Fan levels DDC111 2 operating buttons button Switches to temperature mode for setting the room temperature setpoint button Switches to fan...

Страница 4: ...ge 4 8 Product Description DDC111 DDC111 2 Datasheet 1 10 51 111 01 EN Issue 2012 05 09 Dimensions Connection 82 5 28 3 82 5 RJ9 DDC111 2 DDC111 RJ9 15 cm 0V 5V Tx Rx sw rt gr gl Z178 2 RJ9 10 m Z178...

Страница 5: ...power is switched off The room control module can be mounted on the wall or onto a flush mounted box Choose an installation location that is subject to the air flow of the room to ensure that the room...

Страница 6: ...odule automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching fan levels on or off Fan levels are automatically switched on and off by...

Страница 7: ...the room control module automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching on day or stand by mode The central program automatica...

Страница 8: ...ry fan levels can also be switched manually by the user Manual control Press the button The room control module switches to the manually adjustable fan mode The function symbol is displayed and the cu...

Отзывы: