![Kidde KN-COSM-IBCA Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/kidde/kn-cosm-ibca/kn-cosm-ibca_user-manual_1965105018.webp)
Interconnect Feature
IMPORTANT: This unit is only approved to interconnect
with the Kidde line of products. It is not approved to
interconnect with any other manufacturer's products.
• When compatible smoke alarms (1235CA, 1275CA,
1276CA, 1285CA, i12020CA, i12040CA, i12060CA,
KN-SMFM-ICA, PE120CA, PI2000CA, PI2010CA) and
heat alarms (HD135F) are interconnected to this alarm,
they will only respond to a smoke related event.
• When mixing compatible models with battery backup
(1275CA, 1285CA, i12040CA, i12060CA, PE120CA,
PI2000CA, HD135F, KN-COSM-IBCA, KN-COB-IC-CA,
KN-COP-IC-CA) with models without battery backup
(1235CA, i12020CA, KN-COSM-ICA, KN-COB-ICB-CA,
120X, SM120X, CO120X, SL177i), be advised that the
models without battery backup will not respond during
an AC power failure.
For more information about compatible interconnect units
and their functionality in an interconnect system, visit our
web site at: www.kiddecanada.com
Hush
®
Control Feature
The Hush
®
feature has the capability of temporarily
desensitizing the smoke alarm circuit for about 10 minutes.
This feature is to be used only when a known alarm
condition, such as smoke from cooking, activates the
alarm. You can put the Smoke/CO Alarm in Hush
®
mode by pushing the Test/Reset/Hush
®
button. If the
smoke is not too dense, the alarm will silence immediately,
verbally announce,
"Hush
®
mode on! Mode Hush
®
activé!"
, and the green LED will flash every 2 seconds for
approximately 10 minutes. This indicates that the smoke
alarm is in a temporarily desensitized condition. The alarm
will automatically reset after approximately 10 minutes.
When the unit returns to normal operation after being in
Hush
®
mode, it will verbally announce,
"Hush
®
mode
cancelled! Mode Hush
®
annulé!"
and sound the alarm if
smoke is still present.
Operation
16