manualshive.com logo in svg
background image

User Guide P/N 2544-7202-00-EN 6/2013

ATTENTION: Please take a few minutes to thoroughly read this
user guide, which should be saved for future reference and
passed on to any subsequent owner.

Smoke and Carbon
Monoxide Alarm

User Guide

Model: KN-COSM-IBACA (900-0119)

SINGLE AND/OR MULTIPLE

STATION SMOKE ALARM

SINGLE AND/OR MULTIPLE

STATION CARBON

MONOXIDE ALARM

120 V AC Operated with 2-AA Front-Loading Battery Backup

Содержание i12010SCOCA

Страница 1: ...e which should be saved for future reference and passed on to any subsequent owner Smoke and Carbon Monoxide Alarm User Guide Model KN COSM IBACA 900 0119 SINGLE AND OR MULTIPLE STATION SMOKE ALARM SI...

Страница 2: ...ntil the emergency services responders have arrived the premises have been aired out and your alarm remains in its normal condition 2 Call your local emergency service fire department or 911 Never res...

Страница 3: ...the unit to alarm Careful location of the unit away from the kitchen area will give the maximum nuisance alarm protection Combustion particles from cooking may set off the alarm if located too close t...

Страница 4: ...nd the other should stay to perform a head count Do not reenter under any circumstance until fire officials say that it is safe to do so There are situations where a smoke alarm may not be effective t...

Страница 5: ...e 16 17 Reset Feature Page 17 CO Peak Level Memory Page 17 LED Indicator Operation Page 18 Tamper Resist Feature Page 19 Alarm Removal Page 20 Battery Replacement Page 21 Alarm Replacement Page 21 End...

Страница 6: ...nit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment It is not designed for use in a recreational vehicle RV o...

Страница 7: ...Test Reset Hush Button Green Red LED Light Emitting Diode Battery Compartment Alarm Sounder Voice Speaker 2 Front Product View...

Страница 8: ...Back Product View Tamper Resist Feature AC Connector Pins 3...

Страница 9: ...ce mode CARBON MONOXIDE The alarm voice pattern is four short alarm beeps followed by the verbal warning message WARNING CARBON MONOXIDE This continues until the unit is reset or the CO is eliminated...

Страница 10: ...with a green LED flash twice a second is an indication that the alarm is malfunctioning If this occurs call the Product Support Line at 1 800 880 6788 Test Reset button performs functions See page 15...

Страница 11: ...e possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reaso...

Страница 12: ...r a longer period of time see below for alarm times When a CO condition matches either of these situations the alarm voice message warning system will sound and be accompanied by the flashing red LED...

Страница 13: ...eeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mou...

Страница 14: ...PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 0 9 m 3 0 9 m 3 NOT IN THIS AREA ANYWHERE IN THIS AREA NO...

Страница 15: ...Figure 2B In older mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may cause a thermal barr...

Страница 16: ...accurately detect these conditions Do not install in peaks of vaulted ceilings A frame ceilings or gabled roofs Keep out of damp and humid areas Install at least one 30 5 cm 12 away from fluorescent...

Страница 17: ...ination alarm and detector guard have been evaluated and found suitable for that purpose WARNING The alarm cannot be operated from power derived from a square wave modified square wave or modified sin...

Страница 18: ...t and last unit in an interconnected system is 305 m 1000 Figure 2 illustrates interconnection wiring Improper connection will result in damage to the alarm failure to operate or a shock hazard Make c...

Страница 19: ...TRUCTIONS NOTE AC power should be turned off at this stage attach the mounting bracket to the electrical box To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mount...

Страница 20: ...the alarm always stand an arms length away from the unit when testing After installation TEST THE UNIT S ELECTRONICS by pressing and releasing the test reset button You will then hear the following se...

Страница 21: ...120CA P12040CA Pi2000CA Pi2010CA CO alarms KN COB ICB CA KN COB IC CA KN COP IC CA Combo alarms KN COSM ICA KN COSM IBCA KN COSM IBACA KN COPE ICA Heat alarm HD135F Relay modules SM120X CO120X Strobe...

Страница 22: ...test reset button will silence the alarm If the CO condition that caused the alert continues the alarm will reactivate within 200 seconds CO Peak Level Memory If the green LED is blinking once every...

Страница 23: ...on Standby Condition powered by only battery backup The LED will flash every 60 seconds Alarm Memory Condition The LED will flash every second during alarm When the alarm condition goes away the origi...

Страница 24: ...to engage the mounting bracket Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist featur...

Страница 25: ...W BATTERY as described above and if the green LED flashes twice per second AC power only your unit has malfunctioned Call our toll free Product Support Line at 1 800 880 6788 for instructions on how t...

Страница 26: ...aving time IMPORTANT Constant exposures to high or low humidity may reduce battery life A good safety measure is to replace the battery at least once a year or at the same time as you change your cloc...

Страница 27: ...t or clean inside This action will void your warranty Move the Smoke CO Alarm and place in another location prior to performing any of the following Staining or stripping wood floors or furniture Pain...

Страница 28: ...an enclosed area are all possible sources of CO The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambien...

Страница 29: ...ms of carbon monoxide poisoning are experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test The following symptoms are related to CARBON MONOXIDE POIS...

Страница 30: ...erson stays to account for additional family members Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household t...

Страница 31: ...oned on the previous page might not be reliable enough to provide early warning for unprotected areas that are separated by a door For this reason it is recommended that the householder consider the u...

Страница 32: ...rpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages...

Отзывы: