FEATURES

n

3 Enclosure Configurations

n

Case and Cover - dust and foreign object protection

n

Open Board with Stand-offs - saves space and cost

n

Potted - protection for washdown and exteme vibration

n

Full-time power option

n

Integral Blower Relay

n

2 Wiring Options – 1/4” quick connects and multi-pin connector

n

2 Trial For Ignition Options - 1 and 3 trial

n

4 Trial For Ignition Times - 4, 7, 10 and 15 seconds 

(customized timings available) 

n

2 Flame Sense Options – single spark and sense

and remote sense

n

Diagnostic LED - 3 error codes for accurate troubleshooting

n

Flame Current Test Pins - instant access to circuit 

for troubleshooting

n

Polarity Insensitive – reduces chance of miswiring

APPLICATIONS

n

Construction and Agriculture Heaters

n

Crop Dryers

n

Ceramic and Black Body Infrared Heaters

n

Commercial Cooking Equipment

n

Any 120 VAC Gas Burner Application under 400K BTU

DESCRIPTION

The 35-71 is a 120 VAC direct spark ignition control with 
blower relay for controlling a gas valve, controlling and 
monitoring combustion air-flow and igniting LP or natural gas 
for construction heaters, infrared heaters, crop dryers, 
commercial cooking equipment and gas burner applications 
that provide a 120 VAC operating signal.  

The microprocessor circuit design provides precise, repeatable 
timing sequences for ignition times and purge times (pre-, 
inter- and post-) as well as multiple tries for ignition, 1 hour 
automatic reset and flame sensing during pre-, inter- and post-
purge.  The control continually monitors the pressure switch, 
thermostat and main burner flame to ensure safe system 
operation.  The on-board diagnostics with LED output provide
assistance with troubleshooting to ensure safe and efficient 
burner operation.

Agency Certifications

Recognized under the Component Program of Underwriters Laboratories
Inc., UL 372, UL 1998 Software

Design certified by CSA International, CAN C22.2 #199-M89 
and ANSI Z21.20 Automatic Ignition Systems

SERIES 35-71

120 VAC Direct Spark Ignition Control with 

Combustion Blower Relay - Microprocessor Based

THE TOTAL SOLUTION FOR 
GAS IGNITION CONTROL

Fenwal offers a complete range of ignition 
control products including: 

n

Ignition Controls

n

Spark and Flame Sense Electrodes

n

Spark and Flame Sense Cables 

n

Wiring harnesses

Designed, developed and 
manufactured by Fenwal, 
these components integrate 
seamlessly providing 
maximum system performance.

Getting Started - Samples

To ensure proper system design and operation, Fenwal provides 
sample ignition controls, high-voltage wires and electrodes  for trial 
and evaluation at no charge.  To get you started quickly, Fenwal has 
identified our most popular ignition controls, see Page 8.  Whether 
it is an individual control,  complete start-up kit or customized control, 
Fenwal is ready to provide your gas ignition solution.

Fenwal Ignition Development Center

Send your equipment to us and we’ll design, install and qualify a 
control to meet your exact application requirements.  Fully equipped 
and staffed with trained technicians, the Fenwal Ignition Development
Center has proven extremely beneficial for many customers focused 
on product quality and reducing time-to-market for their appliances.

35-71-01

Series 35-71, 120 VAC Direct Spark Ignition Control

Page 1

www.fenwalcontrols.com

1-800-FENWAL-1

Содержание FENWAL 35-71 Series

Страница 1: ...main burner flame to ensure safe system operation The on board diagnostics with LED output provide assistance with troubleshooting to ensure safe and efficient burner operation Agency Certifications R...

Страница 2: ...resumes If the burner fails to light after the third try the control will de energize the gas valve and go into lockout mode NOTE The Recycle feature option requires a special part number that is det...

Страница 3: ...to 175 F 40 C to 80 C 120 VAC 1 0 microamp minimum 0 8 seconds maximum Natural LP and manufactured Line frequency 50 60 Hz Conformal coated to operate to 95 R H See drawings on Page 8 Integral stand o...

Страница 4: ...on relies on the current passing from ground through the flame to the sense rod The minimum flame current necessary to keep the system operating is 1 0 microamperes SINGLE SPARK AND SENSE Figure 3a RE...

Страница 5: ...se electrodes are designed for on site customization Cut and bend these to fit your application and then send the formed electrode back for Fenwal to detail or send us a print and we will provide you...

Страница 6: ...anded PVC Gray Only 600 V UL CSA Listed 200 C 392 F 18 gage stranded PVC Electrode Assemblies continued REMOTE SENSE Part Number 05 129864 7XX Part Number 05 129864 8XX Part Number 22 100001 080 Part...

Страница 7: ...determined complete the part number by replacing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inches Example 05 129608 018 18 inches...

Страница 8: ...sense Thermostat power off reset 6 3 try remote sense Thermostat power off reset 7 3 try single spark and sense Automatic reset 8 3 try remote sense Automatic reset X X X 35 71 5 X X X 400 MAIN STREE...