Recommended Installation 

Locations

CO alarms should be mounted in or 

near bedrooms and living areas. It is 

recommended that you install a Kidde 

CO alarm on each level of your home.

When choosing your installation 

locations, make sure you can hear the 

alarm from all sleeping areas. If you 

install only one CO alarm in your home, 

install it near bedrooms, not in the basement or furnace room.

• The CO alarm plugs into a wall socket. Children must be taught not to 

handle the CO alarm.

 

Locations To Avoid

IMPORTANT:

 Improper location can affect the sensitive electronic 

components in this alarm. To avoid causing damage to the unit, to provide 

optimum performance, and to prevent unnecessary nuisance alarms:

• Do not install in kitchens, garages or furnace rooms that may expose the 

sensor to substances that could damage or contaminate it.

• Do not install in areas where the temperature is colder than 4.4°C (40°F) 

or hotter than 37.8°C (100°F) such as crawl spaces, attics, porches and 

garages.

• Do not install within 5 ft. of heating or cooking appliances. (Kidde 

recommends 15 ft. to prevent nuisance alarms).

• Do not install near vents, flues, chimneys or any forced/unforced air 

ventilation openings.

• Do not install near ceiling fans, doors, windows or areas directly exposed 

to the weather.

• Do not install in dead air spaces, such as peaks of vaulted ceilings or 

gabled roofs, where CO may not reach the sensor in time to provide early 

warning.

• Do not install this unit near deep-cell large batteries. Large batteries have 

emissions that can cause the alarm to perform at less than optimum 

performance.

• Do not obstruct the vents located on the alarm. Do not place the alarm 

where drapes, furniture or other objects block the flow of air to the 

vents.

3. Installation Locations

DINING

KITCHEN BEDROOM BEDROOM

BEDROOM

LIVING ROOM

Recommended Locations

Содержание 900-0280CA

Страница 1: ...roughly read this user guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User Guide Model KN COP DP 10YLCA 900 0280CA SINGLE STATION CARBON M...

Страница 2: ...2 Call your emergency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the Te...

Страница 3: ...readily see if your smoke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if...

Страница 4: ...igned to protect individuals from acute effects of carbon monoxide exposure It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individua...

Страница 5: ...ed CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also youn...

Страница 6: ...els Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover Possible Sources of Carbon Monoxide Inside your home a...

Страница 7: ...nd Vehicle idling in an open or closed garage or near a home To be safe know the possible sources of CO in your home Keep fuel burning appliances and their chimneys and vents in good working condition...

Страница 8: ...uld fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately have the unit replaced This alarm will not monitor CO levels wh...

Страница 9: ...u a chance to replace the alarm at a more convenient time without sacrificing your safety by disconnecting the alarm from power During this Low Battery HUSH period your alarm is monitoring for CO If t...

Страница 10: ...f unit Life Hush feature allows you to silence End of Unit life chirping for a period of 3 days by pressing the Test Hush button This feature can be used 10 times within 30 days allowing you to replac...

Страница 11: ...or contaminate it Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than 37 8 C 100 F such as crawl spaces attics porches and garages Do not install within 5 ft of heat...

Страница 12: ...lug the alarm in Note This model is equipped with a feature that automatically activates the battery backup when the alarm is plugged into an AC outlet for the first time CAUTION Do not rotate the ala...

Страница 13: ...e battery 6 Operating Characteristics If the alarm senses dangerous levels of CO the digital display will alternate between CO and the measured CO concentration in parts per million PPM and the alarm...

Страница 14: ...m since its last reset or power up The Peak Level display feature will display levels between 30 999 PPM The Peak Level feature is helpful in identifying if you have had a CO reading since resetting t...

Страница 15: ...remove accumulated dust Never use detergents or solvents to clean the alarm Chemicals can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or oth...

Страница 16: ...in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expen...

Отзывы: