background image

Where To Install Your Kidde CO Alarm

The following suggestions are intended to help you with the

placement and installation of your Kidde CO Alarm.
•   Place out of the reach of children. Under no circumstance should chil-

dren be  allowed to handle or install the CO alarm.

•   Install in a bedroom or hallway located close to the sleeping area. Take

special care to verify the alarm can be heard in sleeping areas. 

•   It is recommended that a CO alarm be installed on each level of a multi-

level home.

•   Locate at least [but no closer than] 2 metres away from all fuel burning

appliances.

• Placing at eye level allows for optimum monitoring of the red and green

indicator lights, or, as a guide, 1.5 metres from the floor.

•   Ensure that all vents of the unit are unobstructed.
•   Do not install in dead air spaces such as peaks of vaulted ceilings, or

gabled roofs.

•   Do not install in turbulent air from ceiling fans.  
•   Do not place near fresh air vents or close to doors and windows that

open to the outside.

•   Keep the CO alarm away from excessively dusty, dirty, or greasy areas

such as kitchens, garages and boiler or utility rooms. Dust, grease and

household chemicals can affect the sensor.

•   Keep out of damp and humid areas such as the bathroom.  Avoid spray-

ing aerosols near the CO alarm.

•   Do not install in areas where the temperature is below 40˚F (4.4˚C) or

hotter than 100˚F (37.8˚C).

•   Do not place behind curtains or furniture. CO must be able to reach the

sensor for the unit to accurately detect carbon monoxide. NEVER place

the CO alarm flat on a table top or similar surface.

•   Be aware that certain conditions can result in transient CO situations,

such as: 

1) Excessive spillage or reverse venting off uel burning appliances caused

by outdoor ambient conditions, such as:

i) Wind direction and/or velocity, including high gusts of wind. Heavy air

in the vent pipes (cold/humid air with extended periods between cycles).

Installation Instructions

8

Содержание 900-0259

Страница 1: ...bon Monoxide Alarm please call Kidde Safety Europe on 01753 685148 Please have the following information ready when calling Battery operated CO alarm with Digital Display and Peak Level memory THIS OW...

Страница 2: ...WITH COMMERCIAL AND INDUSTRIAL STANDARDS THIS ALARM IS NOT SUITABLE FOR INSTALLATION IN HAZARDOUS LOCATIONS AS DEFINED IN THE NATIONAL ELECTRICAL CODE INDIVID UALS WITH MEDICAL PROBLEMS MAY CONSIDER...

Страница 3: ...sleepiness and confusion Everyone is sus ceptible to the danger of CO but unborn babies small children preg nant women senior citizens and people with heart or respiratory prob lems may experience sy...

Страница 4: ...rate Peak Level KM 98848 EN 50291 2001 CARBON MONOXIDE ALARM Alarm PPM of Carbon Monoxide Displayed Lb Low Battery Err Error Condition Backlight ModelNo 900 0260 4 900 0260 digital display model Kidde...

Страница 5: ...5 900 0259non digitalmodel Kidde Product View 900 0259...

Страница 6: ...polarity markings at the bot tom of the battery well After approximately 30 seconds your CO alarm will begin monitoring for CO Your Kidde CO Alarm is now operational 6 IMPORTANT A small screwdriver or...

Страница 7: ...your installation locations make sure you can hear the alarm from all sleeping areas If you install only one carbon monoxide alarm in your home install the alarm near bedrooms not in the celler or boi...

Страница 8: ...in turbulent air from ceiling fans Do not place near fresh air vents or close to doors and windows that open to the outside Keep the CO alarm away from excessively dusty dirty or greasy areas such as...

Страница 9: ...ng This CO alarm can be either wall mounted or placed on a tabletop For wall mounting follow these steps 1 Mark the location of the two holes needed on the wall spaced 2 3 8 apart 2 Insert the two scr...

Страница 10: ...You will become accustomed to glancing at the display in much the same manner as you look at a thermometer or clock The unit will not automatically display a reading below 30 PPM However readings bet...

Страница 11: ...mory By pressing the peak level button concentration levels as low as 11 and up to 999 PPM will be displayed Concentrations of CO between 0 and 30 PPM can often occur in normal everyday conditions Con...

Страница 12: ...batteries are removed Unit Replacement Seven years after initial power up this unit will chirp every 30 seconds to indicate that it is time to replace the alarm The unit will not detect CO in this con...

Страница 13: ...the test reset button is pressed numbers appear on the display These are not CO readings and are part of the internal testing process Ignore these numbers Due to the loudness of the alarm we suggest...

Страница 14: ...unit is functioning properly The green light will flash before a CO reading is taken and when any button is pressed If the unit chirps once every 30 seconds observe the unit for the following A chirp...

Страница 15: ...placed in the unit or until the remaining batteries become completely exhausted Three AA batteries have been included with your purchase When replac ing the batteries we recommend use of the followin...

Страница 16: ...tery compartment If applicable the unit will chirp and display for approximately one minute and return to normal operation 4 Gently close the cover The cover of your CO alarm will NOT close if all thr...

Страница 17: ...58 5080 HETAS solid fuel 0845 634 5626 3 Immediately move to fresh air outdoors Do a head count to checkthatallpersonsareaccountedfor Donotre enterthe premises until gas emergency services have arrive...

Страница 18: ...st Severe cases may require treatment in a hyperbaric chamber Remember young children and household pets may be the first effected If you have additional questions please call Kidde on 01753 685148 18...

Страница 19: ...s Safe registered installer Details of local installers can be obtained by ringing Gas Safe 01256 372300 What To Do If The Alarm Sounds THIS CO ALARM MEETS THE FOLLOWING ALARM TIME CONCENTRATIONS REQU...

Страница 20: ...not place near a nappy bucket 20 Move the CO alarm and place in another location prior to per forming any of the following Staining or stripping wood floors or furniture Painting Wall papering Using...

Страница 21: ...If you still have any additional questions regarding error conditions please call us on 0 1753 685 148 Troubleshooting Guide Symptom Problem Action 1 chirp every 30 sec onds with a red LED flash digit...

Страница 22: ...ition of the sensor the alarm readings may vary The digital reading toler ances are Ambient 27 C 12 C 80 F 10 F atmospheric pressure 10 40 3 relative humidity READING TOLERANCE OF DISPLAY READING 0 99...

Страница 23: ...all have no liability for any personal injury property damage or any special incidental contingent or conse quentialdamageofanykindresultingfromgasleakage fireorexplosion Thiswarrantydoesnotaffectyour...

Страница 24: ...Please send products and all other correspondence to Kidde Safety Europe Ltd Mathisen Way Poyle Road Colnbrook Berkshire SL3 0HB contact us at our website at www kiddesafetyeurope co uk...

Отзывы: