5. Using Your Non-Digital Alarm(4MCO) – what the signals mean

LEDs

Sounder

Unit Status

Ac1on

Normal Opera3on

Red

None

Normal Opera3on

None

Amber

Alarm

Red

Flashing

4 loud beeps/pause/4

loud beeps- repeated

CO detected

See sec3on

Amber

Interconnected CO

alarm detects CO

Red

Flashing

4 loud beeps/pause/4

loud beeps- repeated

Interconnected CO alarm

detects CO

See sec3on

Amber

InterconnectedHeat/Smoke

alarmdetects hazard

Red

Flashing

3 loud beeps/pause/3

loud beeps- repeated

Smoke or heat has been

detected from an intercon-

nected smoke or heat alarm

EVACUATE THE PREMISES

ACCORDING TO YOUR ESCAPE

PLAN

Amber

Error condi3on -1

Red

Flashing every 30 secs

Chirp/30 secs

Unit has failed

Replace

Amber Flashing every 30 secs

Error condi3on -2

Red

ON

Constant loud sound Unit microprocessor has

failed

Replace

Amber

End of Life

Red

Flashing

Chirp twice every

30 seconds

The unit has reached the

end of its life

Replace

Amber Flashing twice every 30 secs

Charging the bat-

tery back up

Red

NONE

Ba4ery backup is charging (unit

is monitoring for CO)

Nothing

Amber Flashing every 15 secs

Low ba4ery

Red

Flashing every 15 secs

Chirp / 15 secs

Back up ba4ery is

discharged

Ensure switch is On at the rear

of the unit

-

if it persists

contact Kidde

Amber Flashing every 15 secs

NOTE: If AC mains is connected and ac1ve, the Green LED will be on con1nuous. If Green LED is not on,

see Sec1on 6.

2512-7220-03_v4:_

2016.1.14  2:04 PM  Page 10

Содержание 4MCO

Страница 1: ...e Ba4ery back up User Guide EN50291 1 2010 License No KM98848 4MDCO 4MCO WARNING This alarm will not operate without Mains power During a power failure the unit will operate for at least 24 hours on b...

Страница 2: ...Loca3ons 5 Using Your Alarm what the signals mean 6 Mains Power Failure 7 Interconnected systems 8 What to do if Your Alarm Sounds 9 Maintenance of Your Alarm 10 Troubleshoo3ng 11 Product Speci ca3ons...

Страница 3: ...Test Reset Button Model 4MCO Red Alarm LED Peak Level Button Model 4MDCO LOW BATTERY FLASHING ALARM POWER 1 Flash SERVICE LOW BATTERY POWER FLASHING ALARM 1 Flash SERVICE Model 4MCO EN50291 1 2010 Lic...

Страница 4: ...sed before help arrives It is crucial that the source of CO is determined and appropriate maintenance carried out Carbon monoxide is a cumula3ve poison Longterm exposure to low levels may cause sympto...

Страница 5: ...aintenance of your appliances Contact a licensed contractor or call your local u3lity company for assistance In rented proper1es your Landlord or Council Housing Associa1on will have an Emergency Resp...

Страница 6: ...CO Time un3l Alarm 50 60 90 minutes 100 10 40 minutes 300 Must alarm in less than 3 minutes Parts per Million PPM E ects on Adults 100 Slight headache nausea fa3gue u like symptoms 200 Dizziness and h...

Страница 7: ...oke re or other gas such as natural gas NOTE This product is intended for use in ordinary family homes It is not designed to measure compliance with occupa1onal safety and the HSE NOTE Individuals wit...

Страница 8: ...any wall If there is a par33on in the room locate the alarm on the same side of the par33on as the poten3al source A CO alarm should be installed in all rooms containing a fuel burning appliance Addi3...

Страница 9: ...MS SEE BELOW THIS ALARM IS NOT DESIGNED TO BE INTERCONNECTED WITH OTHER MANUFACTURER S PRODUCTS UNLESS OTHERWISE SPECIFIED Firex Kidde KF10R 1SFWR Mains Ionisa3on Alarm with Rechargeable ba4ery back u...

Страница 10: ...d Flashing every 30 secs Err Chirp 30 secs Unit has failed Replace Amber Flashing every 30 secs Error condi3on 2 Red ON Constant loud sound Unit microprocessor has failed Replace Amber End of Life Red...

Страница 11: ...r Error condi3on 1 Red Flashing every 30 secs Chirp 30 secs Unit has failed Replace Amber Flashing every 30 secs Error condi3on 2 Red ON Constant loud sound Unit microprocessor has failed Replace Ambe...

Страница 12: ...alarm unless it is s3ll detec3ng dangerous levels of CO Peak Level Memory Digital model only Pressing the Peak level memory bu4on tells you if you have had levels of CO 9ppm To reset keep the peak lev...

Страница 13: ...ns has failed Red Flashing every 15 secs Lb and 0 or CO ppm alternate only for the rst 5 minutes Chirp 15 secs Back up ba4ery is dis charged Green Flashing every 7 secs Amber Flashing every 15 secs Ba...

Страница 14: ...very 7 secs Amber OFF Low Ba4ery when mains has failed Red Flashing every 15 secs Chirp 15 secs Back up ba4ery is dis charged Restore the mains ASAP Green Flashing every 7 secs Amber Flashing every 15...

Страница 15: ...nd Press Smoke Heat Alarm test bu4on 3 loud beeps pause 3 beeps with Red LED ashing 3 loud beeps pause 3 loud beeps with Red LED ashing Smoke Heat Alarm Event 3 loud beeps pause 3 loud beeps with Red...

Страница 16: ...nd so on Press Smoke Heat Alarm test bu4on 3 loud beeps pause 3 beeps with Red LED ashing 3 loud beeps pause 3 loud beeps with Red LED ashing Smoke Heat Alarm Event 3 loud beeps pause 3 loud beeps wit...

Страница 17: ...3nues to sound even a er being reset where appropriate then evacuate the premises aler3ng other occupants to the risk Leave doors and windows open Do not re enter the premises 3 Get medical help for a...

Страница 18: ...hair spray near the alarm Do not paint the alarm If decora1ng or using adhesives close to the alarm remove it temporarily NOTE there could be other compounds occurring within a par1cular household whi...

Страница 19: ...d Flashing End Chirp twice every 30 sec onds The unit has reached the end of its life Replace Amber Flashing twice every 30 secs Low ba4ery Red Flashing every 15 secs NONE Chirp 15 secs Backup ba4ery...

Страница 20: ...t Condi3ons 20 C to 60 C 5 95 RH no condensing Temperature Range Opera3ng range 0 C to 40 C Humidity up to 90 rela3ve humidity RH non condensing Alarm Sound 85db at 10 3 metres 3 4 0 5 KHz pulsing ala...

Страница 21: ...ETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION INCLUDING IMPROPER OR MALFUNCTIONING APPLIANCES THE INSTALLATION OF THIS DEVICE SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION USE AND M...

Страница 22: ...liability for any personal injury property damage or any special incidental con1ngent or consequen1al damage of any kind resul1ng from gas leakage re or explosion This warranty does not a ect your st...

Страница 23: ...otec1on Waste electrical products should not be disposed of with household waste Please recycle where facili3es exist Check with Local Authority or retailer for recycling advice 2512 7220 03_v4 _ 2016...

Страница 24: ...mergency Services 0800 111 999 HETAS Solid Fuel Emergency 0845 634 5626 O ec oil 0845 658 5080 Kidde Website www kiddesafetyeurope co uk Manufacturer Address Kidde Safety Europe Limited Made in China...

Отзывы: