wiring instructions for aC quick Connector Harness

 CaUTiON: 

 

Turn off the main power to the circuit before wiring the alarm.

  

For alarms that are used as single station, DO NOT CONNECT THE RED WIRE TO ANYTHING. Leave the 
red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the 
electrical box.

  

When alarms are hardwire interconnected, all interconnected units must be powered from a single circuit.

  

A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. The 
interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms 
total (smoke, CO, Smoke/ CO Combination, heat, etc.). With 18 alarms interconnected, it is still possible to 
interconnect up to a total of 6 remote signaling devices and/or relay modules (see below for details on 
interconnecting Kidde devices).

  

Figure 9-B illustrates interconnection wiring. Improper connection will result in damage to the alarm, failure 
to operate, or a shock hazard.

  

Make certain alarms are wired to a continuous (non-switched) power line.

NOTE:  

Use standard UL Listed household wire (as required by local codes) available at all electrical 

supply stores and most hardware stores.

Figure 9-B,  Interconnect Wiring Diagram

 

Wires on alarm harness:   Connected to:  

 

Black:   Hot side of AC line 

 

White:   Neutral side of AC line 

 

Red:  Interconnect lines (red wires) of other  

 

  units in the multiple station set-up

Additional

Alarm

RED

BLACK

WHITE

Additional

Alarm

RED

BLACK

WHITE

FUSE OR CIRCUIT BREAKER

RED

BLACK

WHITE

Kidde Relay Module

SM120X, CO120X

or both 

Optional 

Accessory

First

Alarm

Содержание 2070-VASCR

Страница 1: ...ia Optical Sensor Smoke Carbon Monoxide Alarm with Voice and Hardwire Interconnect Model 2070 VASCR Hardwire InterconnecT FRONT LOAD battery backup VOICE ALARM COMBINATION ALARM P N 2566 7201 00 Rev A...

Страница 2: ...bustion in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user guide and save the document for future reference and to pass...

Страница 3: ...Features And Specifications 8 6 Limitations Of Smoke And Carbon Monoxide Alarms 9 7 Recommended Locations For Smoke And Carbon Monoxide Alarms 11 8 Locations To Avoid 14 9 Wiring Installation Activat...

Страница 4: ...g up valuables While leaving don t open any inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the...

Страница 5: ...gnizing the importance of the alarm sounding or that might have difficulty leaving the area without help Do not reenter the premises or move away from the open door window until the emergency services...

Страница 6: ...Mode SMART Hush CONTROL Red LED blinks every 2 sec After button push voice Hush Mode Activated Smoke alarm pattern stops If there is too much smoke to allow Hush voice Too Much Smoke Can not be Hushe...

Страница 7: ...ng Your Alarm section Push Test Hush button once to attempt to reset the unit If error continues remove dispose unit and replace as soon as possible Fault CO Sensor Error Chirp every 30 sec voice CO S...

Страница 8: ...r up in permanent marker on the label prior to installing the unit Two labels have been provided that have important information on what to do in case of a CO alarm Place one label at eye level on a w...

Страница 9: ...e additional strategies such as protection in place or assisted escape or rescue are necessary For maximum detection of the various types of fires that can occur within the home including fast flaming...

Страница 10: ...ode It is not designed for use in a recreational vehicle RV or boat The installation of this device should not be used as a substitute for proper installation use and mainte nance of fuel burning appl...

Страница 11: ...are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the s...

Страница 12: ...y shaped ceilings NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4 m horizontally shall be located on the high side of the room NFPA 72 states A row of dete...

Страница 13: ...ation s 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms...

Страница 14: ...cause nuisance alarms or a failure to alarm In very humid areas above 95 RH non condensing as moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed...

Страница 15: ...ng shall be a maximum of 10 ohms The maximum wire run distance between the first and last unit in an interconnected system is 1000 feet The appropriate power source is 120 Volt AC Single Phase supplie...

Страница 16: ...terconnected it is still possible to interconnect up to a total of 6 remote signaling devices and or relay modules see below for details on interconnecting Kidde devices Figure 9 B illustrates interco...

Страница 17: ...the excess wire back into the electrical box through the hole in the center of the mounting bracket Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction NOTE...

Страница 18: ...te the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist feature will help deter children and other...

Страница 19: ...ick connector and locate the small cut out in the middle of the back label Using a screwdriver or similar tool slide the switchin the opposite direction of the LOCK arrow as shown on the label The bat...

Страница 20: ...und if the electronic circuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced Warning Due to the loudness of...

Страница 21: ...ment or 911 This alarm is designed to minimize nuisance alarms Cigarette smoke will not normally cause the unit to alarm unless the smoke is blown directly into the alarm Combustion particles from coo...

Страница 22: ...to section Tamper Resist Features for instructions To replace or install the battery press on the battery carrier and then release to allow the carrier to pop open The battery can then be pulled out...

Страница 23: ...result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of w...

Страница 24: ...problems are especially vulnerable If symptoms of carbon monoxide poisoning are experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test The following...

Страница 25: ...not clear the alarm needs to be replaced Never use detergent or other solvents to clean the unit Avoid spraying air freshener hair spray or other aerosols near the alarm Do not paint the unit Paint w...

Страница 26: ...e what to do in case of fire and where to meet after they leave the house Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practi...

Страница 27: ...resident consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not...

Страница 28: ...de the bedrooms heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hall ways attics furnace rooms closets utility and storage rooms basements and attached garages FCC This devi...

Страница 29: ...l the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this pro...

Отзывы: