14
This smoke alarm uses a 9 V battery (carbon zinc,
alkaline and lithium batteries may be used). A fresh
battery should last for one year under normal operating
conditions.
This alarm has a low battery monitor circuit which will
cause the alarm to “chirp” approximately every 30-40
seconds for a minimum of seven (7) days when the battery
gets low. Replace the battery when this condition occurs.
The low battery chirp will occur approximately 20 seconds
after the red LED flash.
Smoke Sensing Chamber Operation
This alarm will “chirp” if it detects a problem with the
smoke sensing chamber. This chirp will occur about 10
seconds after the flash of the red LED indicator light.
Use only the following 9 V batteries for replacement:
Carbon-Zinc Type
Eveready 1222
Gold Peak 1604S
Alkaline Type
Energizer 522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI,
6AM6X or 6LR61(GA)
Lithium Type
Ultralife U9VL-J
These batteries can be purchased at your local retailer.
WARNING! Use only the batteries specified above. Use of different
batteries than the recommended ones, may have a detrimental
effect on the smoke alarm. A good safety measure is to replace
the battery at least once a year, or at the same time you change
your clocks for daylight saving time. Be sure to follow the battery
installation instructions printed on the back of the alarm.
NOTE: REGULAR WEEKLY TESTING IS REQUIRED!
Maintenance
Содержание 0945CA